2-20
REMOVING THE MAGNETRON THERMAL FUSE
AND THE MAGNETRON
1.Disconnect the electrical power to the
microwave oven.
2.Remove the microwave oven from the
oven cabinet (see pages 2-8 & 2-9 for the
procedure).
3.Open the microwave oven door and re-
move the turntable and rollers.
4.Remove the right side panel (see step 2b
on page 2-10 for the procedure).
CAUTION: Discharge the high voltage ca-
pacitor terminals with a 20,000
Ω
resistor to
chassis ground.
CAUTION:
When you work on the microwave
oven, be careful when handling the sheet metal
parts. Sharp edges may be present, and you
can cut yourself if you are not careful.
c) Remove the remaining T-10 torx screw
from the thermal fuse.
5.
To remove the magnetron thermal fuse:
a) Remove the wires from the thermal
fuse cover clips.
b) Remove the T-10 torx screw from the
thermal fuse cover and remove the
cover.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all panels before operating.
Failure to do so could result in death or
electrical shock.
WARNING
Screw Thermal Fuse Cover
Magnetron
Thermal Fuse
Magnetron
Magnetron Thermal Fuse
Screw
The microwave oven components described
on these pages are shown below.
Summary of Contents for KAC-24