5-12
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Refer to page 4-35 for the procedure for ac-
cessing the hidden bake element.
1. Unplug oven or disconnect power.
2. Set the ohmmeter to the R x 1 scale.
3. Touch the ohmmeter test leads across the
wire connector terminals. The meter should
indicate between 26 and 30
Ω
.
HIDDEN BAKE ELEMENT