5-4
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
DOOR LATCH ASSEMBLY
Latch Motor
Latch Switch
Door Switch
BR
OR
YL WH
TN
BU
Refer to page 4-7 for the procedure for access-
ing the door latch assembly.
1. Unplug oven or disconnect power.
2. Set the ohmmeter to the R x 1K scale.
3. Touch the ohmmeter test leads to the wire
connector terminals. The meter should
indicate as shown below
:
Latch Switch:
(BU) and (TN). The meter
should indicate an open circuit (infinite)
with door unlocked, and a closed circuit
(0
Ω
) with the door locked.
Door Switch:
(OR) and (BR). The meter
should indicate an open circuit (infinite)
with door unlocked, and a closed circuit
(0
Ω
) with the door locked.
Latch Motor:
(YL) and the neutral (WH)
terminal. The meter should indicate ap-
proximately 2450
Ω
.