4
If the following information is not followed exactly, a fi re
causing death or serious injury may occur.
• Do not store a spare LP-gas cylinder under or near this grill.
• Never fi ll the cylinder beyond 80 percent full.
IMPORTANT:
This grill is manufactured for outdoor use only.
For grills that are to be used at elevations above 2000 feet, orifi ce
conversion is required. See “Gas supply requirements” section.
It is the responsibility of the installer to comply with the minimum
installation clearances specifi ed on the model/serial rating plate.
The model/serial rating plate can be found on the heat shield
behind control panel.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
The California Safe Drinking Water and Toxic Enforcement
Act requires the Governor of California to publish a list of
substances known to the State of California to cause cancer,
birth defects, or other reproductive harm, and requires
businesses to warn of potential exposure to such
substances.
WARNING: This product contains a chemical known to the
State of California to cause cancer, birth defects, or other
reproductive harm.
This appliance can cause low-level exposure to some of the
substances listed, including benzene, crystalline silica,
carbon monoxide, toluene, and soot.
In the State of Massachusetts, the following installation
instructions apply:
• Installations and repairs must be performed by a qualifi ed
or licensed contractor, plumber, or gasfi tter qualifi ed or
licensed by the State of Massachusetts.
• If using a ball valve, it shall be a
T-handle type.
• A fl exible gas connector, when used, must not exceed
3 feet.
Materials required for built-in outdoor grill combustible
construction installation:
• Gas line shutoff valve
• 1/2
”
male pipe thread nipple for connection to pressure regulator
• L.P. gas-resistant pipe-joint compound
• CSA design-certifi ed fl exible stainless steel appliance connector
[4-5 ft. (1.2-1.5 m)] or rigid gas supply line as needed
• Noncorrosive leak detection solution
Parts supplied for built-in outdoor grill combustible construction
installation:
• Convertible regulator set for 4
”
W.C. natural gas.
• 2 single-prong plugs / transformer assemblies.
• Rotisserie motor.
• Rotisserie forks.
• Rotisserie spit and handle.
• Insulated jacket.
Parts needed for built-in outdoor grill combustible construction
installation:
The built-in outdoor grills are manufactured for use with natural
gas.
To convert to L.P./propane gas, Gas Conversion Kit no. 4396311
must be used. Follow Instructions included with kit.
Tools needed for built-in outdoor grill combustible construction
installations:
• Level
• Small, fl at-blade screwdriver
• Flat-blade screwdriver
• Phillips screwdriver
• Tape measure or ruler
• Slip-joint pliers
• Pipe wrench
• Scissors or cutting pliers to remove tiedowns
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.