background image

INSTALLATION INSTRUCTIONS

24" (61 CM), 27" (68.6 CM), AND 30" (76.2 CM)

INDOOR/OUTDOOR ELECTRIC WARMING DRAWER 

INSTRUCTIONS D'INSTALLATION

TIROIR-RÉCHAUD ÉLECTRIQUE POUR USAGE

INTÉRIEUR/EXTÉRIEUR DE 24" (61 CM),

27" (68,6 CM), ET 30" (76,2 CM)

Table of Contents/Table des matières

WARMING DRAWER SAFETY ......................................................2

INSTALLATION REQUIREMENTS ................................................3

Tools and Parts ............................................................................3
Location Requirements ................................................................3
Electrical Requirements ...............................................................6

INSTALLATION INSTRUCTIONS ..................................................6

Install Warming Drawer ................................................................6
Complete Installation ...................................................................7

CUSTOM DRAWER FRONT INSTALLATION 
INSTRUCTIONS FOR WARMING DRAWERS..............................7

Tools and Parts ............................................................................7
Install Custom Drawer Front Panel ..............................................7

SÉCURITÉ DU TIROIR-RÉCHAUD ...............................................9

EXIGENCES D’INSTALLATION ...................................................10

Outillage et pièces......................................................................10
Exigences d’emplacement.........................................................10
Spécifications électriques ..........................................................13

INSTRUCTIONS D'INSTALLATION.............................................13

Installation du tiroir-réchaud ......................................................13
Achever l'installation ..................................................................14

INSTRUCTIONS D'INSTALLATION DE LA FAÇADE 
DU TIROIR PERSONNALISÉ POUR TIROIR-RÉCHAUD..........14

Outillage et pièces......................................................................14
Installation du panneau de la façade du tiroir personnalisé ......14

IMPORTANT:

 

Save for local electrical inspector's use.

IMPORTANT :

À conserver pour consultation par l'inspecteur local des installations électriques.

W10713339A

www.goedekers.com

Summary of Contents for 24"

Page 1: ...NSTALLATION INSTRUCTIONS FOR WARMING DRAWERS 7 Tools and Parts 7 Install Custom Drawer Front Panel 7 SÉCURITÉ DU TIROIR RÉCHAUD 9 EXIGENCES D INSTALLATION 10 Outillage et pièces 10 Exigences d emplacement 10 Spécifications électriques 13 INSTRUCTIONS D INSTALLATION 13 Installation du tiroir réchaud 13 Achever l installation 14 INSTRUCTIONS D INSTALLATION DE LA FAÇADE DU TIROIR PERSONNALISÉ POUR TI...

Page 2: ...uctions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANG...

Page 3: ...trical outlet is located in an adjacent cabinet a 1 3 5 cm minimum diameter hole should have been drilled in the back of the cutout or support surface to pass the power supply cord through to the outlet Warming drawer support surface must be solid level and flush with bottom of cabinet cutout Warming drawers with oiled bronze black glass and white glass panels are approved for indoor use only Supp...

Page 4: ...od panel to match your cabinets we recommend consulting a qualified cabinetmaker or carpenter The back of the wood panel must be sealed to avoid moisture damage E D Toe kick Warming drawer cutouts 120 volt grounded outlet or located in adjacent cabinet A A B B C Front view WARMING DRAWER SIZE MINIMUM BETWEEN CUTOUTS A CUTOUT HEIGHT B MINIMUM RECOMMENDED C CUTOUT WIDTH D MINIMUM CABINET WIDTH E 24 ...

Page 5: ...f flush inset cutout minimum 27 69 2 cm 30 76 8 cm B Height between cutouts minimum 2 6 4 cm 2 6 4 cm C Height of flush inset cutout minimum 10 27 3 cm 10 27 3 cm D Bottom of cutout to floor recommended 8 21 0 cm 8 21 0 cm Bottom of cutout to floor minimum 5 12 7 cm 5 12 7 cm E Width of opening minimum 25 64 1 cm 28 71 8 cm F Depth of cutout minimum 25 64 5 cm 25 64 5 cm e Recommended outlet locat...

Page 6: ...ve warming drawer close to its final location Remove and discard shipping materials tape and film from the warming drawer Remove and set aside racks and other parts from inside warming drawer 2 Check that the warming drawer Temperature control knob is set to the OFF position 3 Support the warming drawer on a sturdy surface level with the cutout opening 4 Plug the power supply cord into the grounde...

Page 7: ...pplied 6 8 18 x screws Indicator light lens Parts Needed Custom drawer front Custom handle optional Adhesive recommended for plastic to wood InstallCustomDrawerFrontPanel The warming drawer has an interface that will allow a modest range of panel sizes The actual panel size should be selected by the customer and the contractor to suit the desired effect It is recommended that a qualified carpenter...

Page 8: ...or ON light to be visible through the custom drawer front To secure the lens use an adhesive specified for plastic to wood application 5 Install custom handle not supplied through custom drawer front 6 The custom drawer front is fastened to the stainless steel drawer by driving 6 screws through clearance holes in the drawer front into the wooden or other custom made panel A Optional handle B Custo...

Page 9: ...ect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiels de décès et ...

Page 10: ...la prise électrique est située dans un placard adjacent un trou de 1 3 5 cm de diamètre minimum doit avoir été percé à l arrière de l ouverture ou de la surface de support pour faire passer le cordon d alimentation La surface de support du tiroir réchaud doit être robuste d aplomb et en affleurement avec le bas de l ouverture découpée dans le placard Les tiroirs réchaud avec panneaux en bronze hui...

Page 11: ...staller un panneau personnalisé en bois assorti à vos placards nous vous recommandons de consulter un ébéniste ou un menuisier qualifié L arrière du panneau en bois doit être scellé pour éviter tout dommage dû à l humidité E D Bride de support Ouvertures découpées pour le tiroir réchaud Prise de 120V reliée à la terre ou située dans un placard adjacent A A B B C Vue de face TAILLE DU TIROIR RÉCHAU...

Page 12: ...urement 27 69 2 cm 30 76 8 cm B Hauteur minimale entre les ouvertures 2 6 4 cm 2 6 4 cm C Hauteur minimale de l ouverture intégrée en affleurement 10 27 3cm 10 27 3cm D Distance recommandée du fond de l ouverture au sol 8 21 0 cm 8 21 0 cm Distance minimale du fond de l ouverture au sol 5 12 7 cm 5 12 7 cm E Largeur minimale de l ouverture 25 64 1 cm 28 71 8 cm F Profondeur minimale de l ouverture...

Page 13: ...iaux d emballage le ruban adhésif et le film protecteur du tiroir réchaud Enlever et conserver à part les grilles et autres pièces se trouvant à l intérieur du tiroir réchaud 2 Vérifier que le bouton de commande de la température du tiroir réchaud est réglé à la position OFF arrêt 3 Placer le tiroir réchaud sur une surface robuste de niveau avec l ouverture 4 Brancher le cordon d alimentation sur ...

Page 14: ...18 x Cabochon pour témoin lumineux Pièces nécessaires Façade du tiroir personnalisé Poignée personnalisée facultative Adhésif recommandé pour coller le plastique et le bois Installationdupanneaudelafaçadedu tiroirpersonnalisé L interface du tiroir réchaud permet d installer une gamme modeste de panneaux de différentes dimensions Les dimensions du panneau devraient être choisies par le client et so...

Page 15: ...N en marche à travers la façade du tiroir personnalisé Pour fixer le cabochon utiliser un adhésif recommandé pour coller le plastique et le bois 5 Installer une poignée personnalisée non fournie à travers la façade du tiroir personnalisé 6 Pour fixer la façade du tiroir personnalisé au tiroir en acier inoxydable insérer six vis à travers les trous de passage de la façade du tiroir dans le panneau ...

Page 16: ...W10713339A 2014 All rights reserved Tous droits réservés 11 14 Printed in U S A Imprimé aux É U www goedekers com ...

Reviews: