TECHNICAL DATA EN 14785
Nominal
power
Reduced
power
KE 90 P
Available power
8,6
2,5
kW
Efficiency
86,2
88,0
%
CO emissions at 13% O
2
0,008
0,058
%
Fumes temperature
132
74
°C
Recommended Draught
10
5
Pa
Fuel consumption
2,1
0,6
kg/h
Tank capacity
20
kg
Autonomy
10
33
Heatable volume *
225
m
3
Fumes outlet diameter (male)
80
mm
Air intake diameter (male)
40
mm
Weight including packaging
220
kg
TECHNICAL DATA
* The heatable volume is calculated with a heating demand of 33 Kcal/m³ hour and not considering cooking require-
ments
USER/INSTALLER
TECHNICAL DATA FOR RATING THE FLUE
which must in any case satisfy the requirements of this sheet
and the installation instructions for the product
Nominal
power
Reduced
power
Fumes temperature at smoke outlet
158
89
°C
Minimum draw
0,01
Pa
Fumes flow rate
11,2
6,7
g/s
ELECTRICAL SPECIFICATIONS
Power
230 Vac +/- 10% 50 Hz
Power absorption during ignition
495 W
Power absorption in “heating” function
(Nominale/reduced power)
180/135 W
Power absorption (nominal power) with
Oven Heating , light, fan ON
1730 W
Protection
Fusibile 10 AT, 250 Vac 5x20