4.4 Side Valve Malfunction
Symptoms
Probable Cause
Remedy
Defogger can’t be shut off. Helmet
free flows through defogger.
Seat assembly damaged or debris
under seat.
Clean and/or replace seat
assembly. Check - clean side block
seal area.
Sideblock damaged by debris
Replace sideblock.
Defogger valve will not flow gas.
No air in umbilical.
Turn air on to diver’s supply topside.
Foreign matter in side block or one
way valve.
Disassemble side block one way
valve and clean.
Defogger valve knob hard to turn. Valve stem bent.
Replace valve stem.
4.5 Water Leakage Into Helmet
Symptoms
Probable Cause
Remedy
Water leakage into helmet.
Exhaust valve damaged or stuck
open.
Seat or replace valve.
Communications module O-ring
extruded or damaged.
Replace o-ring.
Communications module not prop-
erly tightened.
Tighten module mount nut.
Communications module
damaged.
Replace
Binding posts or connector seal
damaged.
Remove posts, clean and reseal
with RTV sealant.
Diaphragm damaged or not seated
properly.
Seat or replace diaphragm.
O-ring in neck dam ring damaged
or missing.
Replace o-ring.
Port retainer screws loose.
Tighten screws.
Neck dam torn or damaged.
Replace neck dam.
Hair caught between o-ring and
base of helmet.
Remove hair from this space.
Head cushion or chin strap caught
under o-ring at neck dam.
Clear cushion or dam
Regulator assembled improperly.
Check for proper assembly.
46