![Kirby Morgan SuperLite 27 Operation And Maintenance Manual Download Page 151](http://html.mh-extra.com/html/kirby-morgan/superlite-27/superlite-27_operation-and-maintenance-manual_1971913151.webp)
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130115001
135
SuperLite
®
27
®
Chapter 9.0
Accessories for the SuperLite
®
27
®
Loosen the bent tube.
Remove the free flow knob.
9.1 Introduction
This section provides the manufacturer’s advice on
how to install KMDSI accessories including the hot
water shroud, low pressure inflator hoses, the weld
lens assembly, and accessory mounting brackets.
The installation procedures shown here are typical
for most Kirby Morgan masks and helmets.
9.2 Hot Water Shroud
The Hot Water Shroud (Part #525-100) should be used
whenever diving in water colder than 35.6° F (2°
C).
The KMDSI hot water kit is designed to be integrated
with a hot water supply to help maintain breathing
gas temperature at an acceptable level for the diver.
In addition the hot water reduces the possibility of ice
forming in the demand regulator or gas train compo-
nents. Even with water temperatures of 40° F (4°
C)
the diver can experience discomfort and severe heat
loss through the respiration process. For this reason,
KMDSI recommends installing the hot water shroud
when diving in waters colder than 40° F (4° C).
Water supply to the shroud assembly should be at
least 1 gallon (3.7 liters) per minute at a minimum
temperature of 105° F (42°
C). When diving operations
are conducted during severe cold surface temperatures
a hot water shroud should be used to prevent ice from
developing in and on gas train components while the
diver is on the surface.
9.2.1 Hot Water Shroud Installation
Procedures
Tools Required:
1/4 inch flat blade screwdriver
7/8 inch open end wrench
torque wrench
7/8 inch open end attachment for torque wrench
11/16 inch open end attachment for torque wrench
1) Disconnect the bent tube assembly at the side block
end only. Loosen the jam nut at the regulator. If the
bent tube will not swivel freely, you must loosen the
large nut at the regulator.
2) Remove the defogger knob, locknut, and spring.
3) Remove the emergency valve knob, nut, and spring.
4) Screw the regulator adjustment knob in all the way.
5) To install the rubber regulator cover, slide it over
the bent tube assembly and stretch it over the regula-