![Kirby Morgan SuperLite 27 Operation And Maintenance Manual Download Page 167](http://html.mh-extra.com/html/kirby-morgan/superlite-27/superlite-27_operation-and-maintenance-manual_1971913167.webp)
© ⅯⅯⅩⅢ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 130115001
151
SuperLite
®
27
®
Appendix 3 Table 5 Supply Pressure Guidelines REX
®
Regulator / KM-47 / KM-
77 / and SuperFlow
®
450 Stainless Steel Balanced Regulators
High Pressure Regulated Source
Supply Pressure Guidelines
Depth
Regulator Setting
Surface Gauge in P.S.I.G.
Regulator Setting
Surface Gauge in BAR
FSW
MSW
Minimum
P.S.I.G.
Maximum
P.S.I.G.
Minimum
Bar
Maximum
Bar
0-60
0-18
140
200
9.7
13.8
61-100
19-30
165
220
11.4
15
101-132
31-40
180
250
12.4
17
133-165
41-50
220
300
15
20.7
*166-220
51-67
270
300
18.6
20.7
Appendix 4 Standard Kirby Morgan Surface Supply Pressure
Formula - Old Method
Old Pressure Table Calculation:
The old method of determining supply pressure was to multiply the dive depth by .445 PSI and then add the
over-bottom pressure called out in the depth ranges for the depth from the KMDSI operations manual. The old
method was based on a minimum RMV of 62.5. This method can still be used. The old method used the formula
and called out over bottom pressures for depth as follows [(FSW x .445) + PSIG for depth] from the table below.
Depth in Feet and Meters
Over Bottom Pressure
0-60 FSW
(0-18 MSW)
90 PSIG (6.2 Bar)
61-100
(18-30) 115
(7.9)
101-132
(30-40)
135 (9.3)
133-165 (40-50)
165 (11.4)
166-220 (50-67)
225 (15.5)
For more information on determining supply pressure related information check the Dive Lab web site at www.
divelab.com.