Inspection, Repair and Trouble Shooting for the Welder and Generator Set

5.1 Maintenance and rimedy

Th

e g

en

era

to

r d

oe

s n

ot 

ge

ne

ra

te

th

e e

lec

tric

ity,

 w

ith

ou

t w

eld

er 

vo

lta

ge

.

T

h

e

 d

ie

s

e

l e

n

g

in

e

 c

a

n

 n

o

 s

ta

rt

Remedy

Cause

Oil fuel is not enough

The switch is not at  ON  position

Check the level of lubricant

The oil nozzle has dirty

The battery has no electricity

Main switch (NFB) is not closed

The contact of socket is not good

AVR auto-voltage regulator is damaged

The pump of high pressure and oil nozzle
can not inject oil or the oil amount is not enough

The control lever of speed is not at  RUN  position

The speed and force to pull the recoil starter is not enough

The carbon brush of generator is not good

The rated speed of generator ban not be reached

The potentiometer for adjusting the welder current is damaged

Add oil fuel.

Turn it to  ON  position.

Put the control level to  RUN  position.

Clean the oil nozzle.

Charge it or replace it with a new one.

Put the main switch to the  ON  position.

Change the carbon brush.

Adjust the feet of socket.

Adjust if according to the requirements.

Change the AVR auto-voltage regulator.

Change the potentiometer.

Remove the oil nozzle out and repair it at test table.

The specified oil level should be between

upper level  H  and lower lever  L 

Start the diesel engine according to the
requirements of operating procedure of start.

If electricity is still not generated, take the generator to a our Dealer.

5.2 Question and problem

If you have any question or problem when you meet in your operation, please 
contact with our company or our dealer and tell the following information:
(1) The type of diesel generator sets, the No. and type of diesel engine and the 
No. and type of generator.
(2) Status
What problem had been taken place when operation and explain how much 
speed it is operated.
(3) Time of operation
(4) The other cetailed conditions, for example, when the problem took and what 
time, etc.
For details, please fill the sheet of soliciting opinions from the customers and 
send it to our company.

-

-

4.2 Maintenance for a long time storage

If your generator should be storage in a long time, the following preparation 

should be made:

4.2.1 Operate the diesel engine about 3 minutes, the stop it.

4.2.2 Close the diesel engine when the diesel engine is still hot, drain old 

lubricate of diesel engine oil out, the refill new one.

4.2.3 Pull out the rubber plug at the cover of diesel engine and ass 2ml of 

lubricate in cylinder, and finally put the plug on its original place.

4.2.4 Maintenance of starting position

(1) Manual starting

Press the pressure-reduce handle (non-compressin position), pull the recoil 

handle 2~3 times. (Don't start the diesel engine).

(2) Electric starting 

When the starting handle is in the position of non-compressing position, operate 

the diesel engine 2~3 seconds. When the switch is in the position of istart, don't 

start the diesel engine.

4.2.5 Pull the pressure-reduce handle out, pull the recoil starter slowly.

When fell it is fasten, then stop. (At this time the intake and drain valve is at the 

status of close, it is suitable to prevent from rust).

4.2.6 Clean and store it in a dry place.

-

-

Summary of Contents for KDE180EW

Page 1: ...AIR COOLED DIESEL WELDER AND GENERATOR SET KDE180XW KDE180EW KDE180TW...

Page 2: ......

Page 3: ...erator Set 3 6 How to operate the Welder and Generator Set 3 7 Loading 3 8 Breaking the Welder and Generator Set 3 9 KDE180 Set 4 Maintenance of the Welder and Generator Set 4 1 Regular Maintenance 4...

Page 4: ...tion oil Start battery Combustion oil tank volume L Low oil pressure stop protection system Cylinder diameter Stroke mm Continuous operation for 10 hours Three phase IGBT PWM Transmission shaft rigid...

Page 5: ...sy Capacitor Welding output terminal post assembly No Parts No Description Qty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 QF1 V HL X1 X2 SA DT FU1 Z1 Z2 W1 W2 W3 W4 W5...

Page 6: ...sonal accidents and the equipment damages may be caused 3 1 1 Fire prevention The combustion oil used in the diesel engine is light diesel oil The gasoline kerosene and other oils should not be used U...

Page 7: ...tion NOTE Potentiometer Electric Lock Wiring Terminal AC Output Receptacle Grounding Terminal Automatic Air Switch Fuse 8 a b 3 2 Preparation before the Start 3 2 1 Select and treat with combustion oi...

Page 8: ...t About one month or 20 hours Interval of 3 months or 100 hours Time for changing the oil Top Limit Lower Limit Although there are the low oil pressure alarm system the stop device At the time of star...

Page 9: ...ion pump and the oil transmission pipe so as to discharge the air in the fuel oil until there is no air bubbles to be appeared Then fasten the connecting nut again Potentiometer Electric Lock DC Outpu...

Page 10: ...relieve the switch handle Let the switch restore to ON position automatically 5 If the diesel engine doesn t start after 10 seconds please wait for anther 15 seconds and make the start again If the st...

Page 11: ...ark add some distilled water to make that the liquid level goes up to a higher mark If the electrolyte in the battery is too less the diesel engine will not start Because the electric power is insuffi...

Page 12: ...op immediately It is necessary to check the oil height and add some oil 3 Do not unfasten the adjustment bolt used for adjusting the speed limit of the diesel engine or do not unfasten the high pressu...

Page 13: ...the switching board By adjusting to a suitable position the welding can be carried out If a smaller current is needed it is possible to reduce the not be used for a long time The position for the rate...

Page 14: ...used only for the welding separately the welding cable should be removed or protected When the set is used only for the welding separately the air switch should be turned off or the power supply plug...

Page 15: ...justvalveclearanceforintakeandexhaustvalves Check commutator brush and slip ring Every year or 1000 Hrs Daily check First month of 20 Hrs Every 3 months or 100 Hrs Every 6 month or 500 Hrs 1st time 2n...

Page 16: ...ator clock whether they are in good condition If spark occurs they have to be adjusted properly Every 3 months or 100 hours Clean time monthly Battery fluid check 4 1 1 Changing engine oil Every 100Hr...

Page 17: ...f you have any question or problem when you meet in your operation please contact with our company or our dealer and tell the following information 1 The type of diesel generator sets the No and type...

Page 18: ...the cable will be burnt If the cable is long and thin the input voltage of the electric appliance will be not enough causing that the generator doesn t start In the following formula you can calculate...

Page 19: ...t is C 0 03 When the relative humidity is 100 the modified coefficient is C 0 04 Counting example When the rated power of generator is P 5KW altitude is 1000m ambient N temperature is 35 relative humi...

Reviews: