32
10.TROUBLESHOOTING
When the engine will not start:
Refill the fuel tank.
Turn the engine switch on.
Add the recommended oil.
Is there fuel in the tank?
Is the engine switch on?
YES
NO
YES
YES
NO
NO
NO
Still no
spark
Replace the
spark plug.
WARNING
To check:
1)Remove the spark plug cap and clean
any dirt from around the spark plug.
2)Remove the spark plug and install the
spark plug in the plug cap.
3)Set the plug side electrode on the
cylinder head to ground.
4)Pull the recoil starter, sparks should jump
across the gap.
If the engine still does not
start, take the generator to
an authorized dealer.
Is the fuel reaching the
carburetor.
Take the generator to
an authorized dealer.
Is there enough oil in the engine?
Is there a spark from
the spark plug?
Be sure there is no spilled
fuel around the spark pulg.
Spilled fuel may ignite.
5
Control panel
Smart Throttle switch
DC receptacle
Ground terminal
Output indicator light
Overload indicator light
Low oil alarm indicator light
AC receptacle
Parallel
Engine speed is kept at idle automatically when the electrical appliance is
disconnected and it returns to the proper speed to power of the electrical load
when elec-trical appliance is connected. This position is recommended to
minimize the fuel consumption while in operation.
receptacle
The parallel cabinet can be connected with the parallel socket when the
generator set needs a increasing of parallel output power.
SMART throttle
Smart throttle
switch
Smart throttle system does not operate effectively if the electrical appliance
requires the big electric power.
When high electrical loads are connected simultaneously turn the smart
throttle switch to the OFF position to re-duce voltage changes.
In DC charging, turn the smart throttle switch to the OFF position.
OFF:
Note: Smart throttle system does not operate. Engine speed is kept at thigh-
speed lever..
NOTE
Parallel
receptacle