24
1.CHANGING OIL
Drain the oil while the engine is still warm to assure rapid and complete draining.
1.Loosen the cover screw and remove the left side maintenance cover.
2.Remove the oil filler cap.
3.Drain dirty oil into a container thoroughly.
4.Refill with the recommended oil, and check the oil level.
5.Reinstall the left side maintenance cover and tighten the cover screw securely.
Engine oil capacity:0.25L
Make sure to turn the engine switch and the fuel cap lever OFF before
draining.
CAUTION
Please dispose of used motor oil in a manner that is compatible with the
environment. We suggest you take it in a sealed container to your local
service station for reclamation. Do not throw it in the trash or pour it on the
ground.
NOTE
Wash your hands with soap and water after handing used oil.
13
6.GENERATOR USE
Connections for standby power to a building's electrical system must be
made by a qualified electrician and must comply with all applicable laws
and electrical codes. Improper connections can allow electrical current from
the generator to backfeed into the utility lines. Such backfeed may
electrocute utility company workers or others who contact the lines during a
power outage, and when utility power is restored,the generator may
explode, burn, or cause fires in the building's electrical system.
To prevent electrical shock from faulty appliances, the generator should be
grounded.Connect a length of heavy wire between the generator's ground
terminal and an external ground source.
CAUTION
Maximum power would be available for the first 30 minutes.
For continuous operation,do not exceed the rated power. In either case, the
total wattage of all appliances con-nected must be considered.
Do not exceed the current limit specified for any one receptacle.
Do not connect the generator to a household circuit. This could cause the
damage to the generator or to electrical appliances in the house.
Do not modify or use the generator for other purposes than it is intended
for. Also observe the following when using the generator.
Do not connect an extension to the exhaust pipe.
When an extension cable is required,be sure to use a tough rubber
sheathed flexible cable. (IEC245DV equivalent)
2
Limit length of extension cables; less than60 m for cables if 2.5mm and
2
less than100m for cabes of 4 mm .
Keep the generator away from other electric cables or wires such as
commercial power supply lines.
WARNING
Fuse
Fu
se
Maintenance cover
Screw
Oil filler cap
Oil filler cap
Upper level