1. Before starting the genset, disconnect the load from the DC terminals.
Ensure the breaker is kept at "OFF"
2.
Turn the switch to the start position, then generator begins to preheat automatically.
Loose it after all lamps lit, the switch returns to "ON", which means generator starts
successfully. For start failure, please restart the generator after waiting for 10 minutes.
The purpose of the maintenance and adjustment schedule is to keep the generator in
the best operating condition.
Shut off the engine before performing any maintenance. If
the engine must be run, make sure the area is well ventilated.
The exhaust contains poisonous carbon monoxide gas.
Use genuine our parts or their equivalent. The use of
replacement parts which are not of equivalent qual-ity may
damage the generator.
Maintenance Schedule
NOTE: (1) "O" means normal maintenance interval
(2) "O(2)" means generator used in dirty area. Please shorten the maintenance interval
(3) "O(3)" means maintenance and repair should taken by KIPOR dealer unless
professionals are available. Please refer to the maintenance manual.
1. CHANGING OIL
Run generator for 3
5 minutes and stop it. Drain the oil quickly when the generator is
heated.
Ensure the generator is stopped before drainage.
-
-
-
-
(
)
first time
(
)
Replace
(2)
(3)
(3)
(
)
after second time
5. STARTING THE GENERATOR
8. MAINTENANCE
Item
Each
use
First
month
or
20 hours
Every 3
months
or
50 hours
Every 6
months
or 100
hours
Every
year
or 200
hours
Regular service period
Oil
Oil filter
Air filter
Nozzle pump
Valve clearance
Tank and filter
Oil circuit
Check
Replace
Check
Clean
Clean adjust
Check adjust
Check
Check and replace
Clean or replace
(
)
after second time
Every 2 years(replace if necessary)(3)
CAUTION
WARNING
WARNING
Breaker