4
2.
Fuel Specification.
The burner should only be supplied by fuel with the following properties:
Fractions
grain size
Diameter
6±1mm, 8±1mm
Length
3,15mm - 40 mm
Dust fraction
≤ 1%
Density
≥ 600 kg/m
3
Moistness
≤ 10%
Calorific value
16,5÷19 MJ/kg
Ash content
≤ 0,7%
Nominal power of the burners is given for the use of pellets produced in accordance
with DIN or DIN Plus Specifications. For pellets with other combustion parameters, in par-
ticular with a different calorific value, ash level and moisture - the power of the burner may
be different, usually smaller.
3.
Construction and Operation of the Burner.
No.
Description
1.
Rotary combustion chamber
2.
Aeration chamber rotary
3.
Thermal insulation (option)
4.
Bearing of the aeration chamber and the combustion
chamber
5.
Blower chamber
6.
Connection elbow for pellet feeding
7.
Flexible pipe connector - meltable
8.
External tray fuel feeder
9.
External fuel tray (option)
10.
Fan
11.
Mechanism for combustion chamber rotation
12.
Fuel feeder into the combustion chamber (stoker)
13.
Igniter
Summary of Contents for ROT-POWER 10-50 kW
Page 5: ...5 Fig 1 Block diagram of the burner ...
Page 9: ...9 Fig 2 Components of the set ...
Page 22: ...22 Fig 8 Cleaning the tubular blower chamber view 1 ...
Page 23: ...23 Fig 9 Cleaning the tubular blower chamber view 2 ...
Page 27: ...27 Fig 11 Lubricating the bearings of the combustion chamber view 1 ...
Page 28: ...28 Fig 12 Lubricating the bearings of the combustion chamber view 2 ...
Page 30: ...30 Fig 13 Igniter Replacement ...
Page 34: ...34 12 2 Electric diagram of the burner Fig 15 Wiring diagram of the burner where ...