24
9.3.
Adjusting the blow intensity into the combustion chamber.
*
Depending on your needs, the amount of air provided to the combustion bed may be
adjusted. To make this adjustment, follow the instructions below.
1.
Loosen the fixing screws (1) that secure the burner housing -2 pcs.
2.
Remove the burner housing (2).
3.
Use an Allen key size 5 (4) to turn the screw (3). Counter-clockwise rotation to decrease
the airflow, while clockwise rotation increases it. Rotation from the minimum to the ma-
ximum airflow is 90
0
.
4.
After finishing the adjustment, replace the burner housing (2) and tighten the screws (1).
Fig. 10. Adjusting the blow intensity into the combustion chamber.
* - Not applicable burners 4-16 kW and 5-20 kW.