background image

 

 

 
 
 
 
 
 

LED 

LED 

condition 

Module operation 

condition 

Power 

 

 

ON 

Power on. 

 

OFF 

Power off. 

Connection 

with a 

controller 

 

 

ON 

Active  connection  of  the 
controller.   

 

OFF 

No 

connection 

with 

controller. 

Connection 

with WiFi 

 

 

ON 

Connection 

to 

programmed 

wireless 

network is on. 

 

OFF 

No 

connection 

with 

wireless network. 

Connection 

with a server 

 

 

ON 

Connection 

with 

www.econet24.com 
external server is on. 

 

OFF 

No 

connection 

for 

www.econet24.com 
external server. 

After  the  power  is  on,  ecoNET300  requires 
app.  1  minute  in  order  to  load  the 
operational system. Then, the module begins 
to  work  and  indicates  its  condition  with  LED 
indicators. 

In 

connection 

between 

ecoNET300  module  with  a  controller  is 

active,  a  “

connection  with  controller

” 

indicator  lights  up.  New  functions  for 

managing  ecoNET300  module  are  added  to 
the main menu. 

MENU

 

 

Information

 

 

ecoNET WiFi

 

MENU

 

 

Information

 

 

ecoNET Ethernet 

MENU

 

 

Main settings

 

 

WiFi

 

 

 

 

 

In case of connection with LAN wire network, 

ecoNET  Ethernet

  tab  will  be  available  in 

controller  menu  from  which  the 

IP

  number, 

mask  and  gate  can  be  read  out  and 
ecoNET24 server connection condition can be 
checked. It is required to save the displayed 

IP

  number  (e.g.  IP:10.1.2.237).  This 

number  in  a  form  of:  http://10.1.2.237  is 
entered into the address field  from the level 
of  LAN  network.  A  website  to  operate  the 
controller menu will be activated. 
 
It  is  necessary  to  enter  network  parameters 
in 

General  settings

  menu  of  the  control 

panel in order to make a wireless connection 
via Wi-Fi.  
To do this, select: 

MENU 

  general  settings 

  WiFi  (WiFi 

settings) 

Select 

SSID

  in 

Network  Settings

.  It  is  a 

name of the local wireless network which has 
to be the same for all devices working in this 
network (SSID can be, e.g.: myWiFi). 

 

 
In  case  of  connection  with  a  chosen  Access 
Point via wireless network, user has to know 
the  settings  of  Wi-Fi  network  which  the 
module will be connected to: network name 
(SSID), protection type, access password. 

 
The ecoNET300 requires active DHCP server 
of  Access  Point  (e.g.  router)  because 
manual  IP  assignment  for  ecoNET300 
internet  module  is  not  supported.  More 
information  can  be  obtained  from  router 
configuration 

software 

or 

network 

administrator. 

WPS/RESET  button.  Deleting  user  name 
and  password  and  restoring  default 
settings.  
 
The  LED  indicators  of  module  operation 
condition. 
 

Summary of Contents for ecoNET300 Series

Page 1: ...INSTALLATION MANUAL ISSUE 1 1_EN APPLIES TO THE BOILER CONTROLLERS SERIES ecoMAX850 ecoMAX860 ecoMAX920 THE WEB MODULE ecoNET300 REMOTE CONTROL OF BOILER CONTROLLERS 04 2020 www econet24 com ecoNET a...

Page 2: ......

Page 3: ...CONNECTION WITH ECOMAX860P3 6 6 3 CONNECTION WITH ECOMAX920 6 7 CONNECTION WITH INTERNET 6 8 LOGGING TO ECONET ACCOUNT 8 8 1 FIRST LOGGING TO ECONET ACCOUNT 8 9 WEBSITE SUPPORT 9 9 1 CURRENT DATA 9 9...

Page 4: ...mentioned above you avoid harmful effects on the environment and human health 3 General informations The internet module enables controller operation remote control on line via Internet User can remot...

Page 5: ...ne COM transmission socket in RJ11 standard which a control panel located inside or outside the controller housing is connected to Using one RJ11 socket in the module requires connecting an additional...

Page 6: ...and 3G USB Port to the ecoLINK2 interface Connect with RJ45 Ethernet Port with Ethernet cable e g with ADSL router switch and modem A socket does not have to be use in case of Wi Fi wireless network...

Page 7: ...e read out and ecoNET24 server connection condition can be checked It is required to save the displayed IP number e g IP 10 1 2 237 This number in a form of http 10 1 2 237 is entered into the address...

Page 8: ...word for an existing account we choose FORGOT PASSWORD and enter your email A password reminder will be sent to your email account 8 1 First logging to ecoNET account In case of first logging user has...

Page 9: ...entering the service password Data history Data archive of selected controller operation parameters Alarms List of controller alarms Schedule Work schedule of the controller and temperature reduction...

Page 10: ...meter value with the slider and confirm with the Save button Exit with modification without saving a new setting is possible by clicking on the symbol 9 4 Data history The Data history tab enables to...

Page 11: ...er can read the fuel consumption in kilograms in a daily cycle every 1 hour or a monthly cycle every 1 day 9 8 Device settings The Device settings tab enables to change the controller installation add...

Page 12: ...300 module has to be connected to power supply 1 Push WPS RESET button during normal module operation 2 Hold this button pressed for at least 10 seconds 3 Release the WPS RESET button 4 A LED indicato...

Page 13: ...his License and to the absence of any warranty and give any other recipients of the Program a copy of this License along with the Program You may charge a fee for the physical act of transferring a co...

Page 14: ...ted by the Free Software Foundation write to the Free Software Foundation we sometimes make exceptions for this Our decision will be guided by the two goals of preserving the free status of all deriva...

Page 15: ...15...

Page 16: ...ul Obornicka 71 62 002 Suchy Las Poland Phone 22 61 811 70 37 biuro kipi pl www kipi pl National Waste Database No 000179569...

Reviews: