KIPI ecoNET300 Series Operation And Installation Manual Download Page 11

11 

 

In the 

Alarms

 tab, user can read: 

 

a  list  of  registered  alarms  and  other 
events sent by the controller, 

 

 a  type  of  alarm,  event  and  period  of  its 
occurrence is displayed. 

Log  into 

www.econet24.com

  external 

server  in  order  to  display  all  logs  of  alarm 
conditions from the beginning of operation of 
the controller.  
Alarm  notices  can  be  sent  on  e-mail.  It 
enables  the  user  to  react  fast  in  order  to 
restore normal operation of the controller. 

9.6

 

Schedule 

In the 

Schedule

 tab user have the option of 

setting  the  time  intervals,  according  to  the 

list after clicking on the 

 symbol: 

 

reduction  preset  temperature  of  the 
heating circuits. 

Turn on the schedule by selecting 

On

 for the 

available  circulation  from  the  list,  and  enter 
the  decreasing  temperature  value  in  the 

Decrease

  field,  .e.g. 

10°C

.  On  a  bar  chart 

daily  graph  (24  hours),  click  on  the 
appropriate bars (each bar corresponds to 30 
minutes),  which  allows  to  set  the  active 
temperature  reduction  in  the  selected  time 
interval. Once set, choose 

Save

.  

Decreasing of preset temperature can be set 
separately for all days of the week. 

 

In  the  example  above,  on  Tuesday,  the 
preset  temperature  for  the  heating  circuit  is 

reduced by 10°C between 6:00 and 7:30 and 

15:30  to  19:00.  In  other  ranges,  the  preset 
temperature will not be lowered. 

9.7

 

Fuel consumption 

In the 

Fuel consumption

 tab user can read 

the  fuel  consumption  in  kilograms  in  a  daily 
cycle  (every  1  hour)  or  a  monthly  cycle 
(every 1 day). 

 

9.8

 

Device settings 

The 

Device settings

 tab enables to:  

 

change the controller installation address, 

 

reading basic Wi-Fi network parameters, 

 

readout  a  software  version  in  the 
controller module and additional modules 
or panels, 

 

update internal ecoNET300 software. 

The  ecoNET24  server  periodically  checks 
availability  of  new  software  version  for  the 
ecoNET300  module.  It  displays  information 
concerning  a  new  software  version.  All  the 
user needs to do is to press 

Update 

button. 

 

 

When changing Wi-Fi network, click 

Refresh

select 

Network  name

,  and  used 

Type  of 

security

  (e.g.  WPA2  Personal)  and  enter 

Password

 to a selected network. 

All modifications must be confirmed by 

Save 

button. 

10.

 

Mobile application 

The  mobile  application  allows  remote  access 
via  smartphone,  tablet  only  to  controllers 
equipped  with  the  ecoNET300  internet 
module.  The  application  uses  an  Internet 
connection  and  a  user  account  on  the 

www.econet24.com

 website. 

 

 

The  application  allows  to  preview  and 
efficiently  configure  the  most  important 
parameters  of  the  controller.  In  this  regard, 
it primarily provides: 

• preview basic operating parameters

 

 
The  applications  works  only  with  ecoNET24 
server,  so  should  be  need  to  sign  up  for  an 
ecoNET account to use them. 

 
Software  update  process  can  be  shorter  or 
longer  depending  on  the  speed  of  Internet 
connection.  Do  not  disconnect  the  device 
from  a  power  supply  during  update  process 
because it will cause its damage. 

Summary of Contents for ecoNET300 Series

Page 1: ...INSTALLATION MANUAL ISSUE 1 1_EN APPLIES TO THE BOILER CONTROLLERS SERIES ecoMAX850 ecoMAX860 ecoMAX920 THE WEB MODULE ecoNET300 REMOTE CONTROL OF BOILER CONTROLLERS 04 2020 www econet24 com ecoNET a...

Page 2: ......

Page 3: ...CONNECTION WITH ECOMAX860P3 6 6 3 CONNECTION WITH ECOMAX920 6 7 CONNECTION WITH INTERNET 6 8 LOGGING TO ECONET ACCOUNT 8 8 1 FIRST LOGGING TO ECONET ACCOUNT 8 9 WEBSITE SUPPORT 9 9 1 CURRENT DATA 9 9...

Page 4: ...mentioned above you avoid harmful effects on the environment and human health 3 General informations The internet module enables controller operation remote control on line via Internet User can remot...

Page 5: ...ne COM transmission socket in RJ11 standard which a control panel located inside or outside the controller housing is connected to Using one RJ11 socket in the module requires connecting an additional...

Page 6: ...and 3G USB Port to the ecoLINK2 interface Connect with RJ45 Ethernet Port with Ethernet cable e g with ADSL router switch and modem A socket does not have to be use in case of Wi Fi wireless network...

Page 7: ...e read out and ecoNET24 server connection condition can be checked It is required to save the displayed IP number e g IP 10 1 2 237 This number in a form of http 10 1 2 237 is entered into the address...

Page 8: ...word for an existing account we choose FORGOT PASSWORD and enter your email A password reminder will be sent to your email account 8 1 First logging to ecoNET account In case of first logging user has...

Page 9: ...entering the service password Data history Data archive of selected controller operation parameters Alarms List of controller alarms Schedule Work schedule of the controller and temperature reduction...

Page 10: ...meter value with the slider and confirm with the Save button Exit with modification without saving a new setting is possible by clicking on the symbol 9 4 Data history The Data history tab enables to...

Page 11: ...er can read the fuel consumption in kilograms in a daily cycle every 1 hour or a monthly cycle every 1 day 9 8 Device settings The Device settings tab enables to change the controller installation add...

Page 12: ...300 module has to be connected to power supply 1 Push WPS RESET button during normal module operation 2 Hold this button pressed for at least 10 seconds 3 Release the WPS RESET button 4 A LED indicato...

Page 13: ...his License and to the absence of any warranty and give any other recipients of the Program a copy of this License along with the Program You may charge a fee for the physical act of transferring a co...

Page 14: ...ted by the Free Software Foundation write to the Free Software Foundation we sometimes make exceptions for this Our decision will be guided by the two goals of preserving the free status of all deriva...

Page 15: ...15...

Page 16: ...ul Obornicka 71 62 002 Suchy Las Poland Phone 22 61 811 70 37 biuro kipi pl www kipi pl National Waste Database No 000179569...

Reviews: