5.

 

Cooperation with controllers 

  

 

Check  controller  software  version  before 
connecting  a  ecoNET300  module  with  the 
controller. 
In the controller main menu select tab: 

MENU 

 Information 

 Software version

 

User  can  contact  with  the  controller 
manufacture  in  order  to  verify  whether  a 
particular  type  of  controller  will  be 
cooperating  with  ecoNET300  according  to 
data concerning controller software versions. 

6.

 

Connection to the controller 

 

 

The  ecoNET300  internet  module  has  to  be 
connected  with  controller  with  the  use  of 
ecoLINK2 interface. In case of some types of 
controllers  it  is  necessary  to  use  an 
appropriate  adapter.  The  ecoLINK2  interface 
and adapter are a part of the ecoNET300 set.  

 

 

 

Adapter: 1 - socket for RJ11 ecoLINK2 interface, 2 
- a plug for controller module transmission socket, 
3 - socket for a control panel plug. 

6.1

 

Connection with ecoMAX850P2 

The  ecoMAX850P2  controllers  are  equipped 
with  just  one  COM  transmission  socket  in 
RJ11 standard which a control panel (located 
inside  or  outside  the  controller  housing)  is 
connected  to.  Using  one  RJ11  socket  in  the 
module  requires  connecting  an  additional 
divider  (telephone  RJ11  tee  separator)  and 
additional cable. 

 

Standard  divider,  RJ11  telephone  divider:  1- 
connection  of  RJ11  ecoLINK2  interface  plug,  2- 
connection  of  the  control  panel  plug,  3- 
connection  of  an  additional  cable  with  two  RJ11 
terminals. 

 

Standard  RJ11  telephone  cable  with  an  option  of 
connecting wires and a method of connecting into 
the divider. 

 
Below  show  location  of  the  controller  COM 
transmission 

socket, 

where: 

interface 

ecoLINK2,on 

diagram 

includes: 

COM 

transmission 

socket 

(connection 

point 

between  cable  and  divider),  divider,  control 
panel,  additional  room  panel  and  additional 
cable to a divider. 

 
In  order  to  connect  the  ecoNET300  module 
with  the  controller,  ecoLINK2  interface  is 
required which is a part of the set. 

 
The internet module will cooperate only with 
controllers with installed software supporting 
ecoNET300 module. 

 
In  any  circumstances  do  not  modify 
construction of the device. 

Summary of Contents for ecoNET300 Series

Page 1: ...INSTALLATION MANUAL ISSUE 1 1_EN APPLIES TO THE BOILER CONTROLLERS SERIES ecoMAX850 ecoMAX860 ecoMAX920 THE WEB MODULE ecoNET300 REMOTE CONTROL OF BOILER CONTROLLERS 04 2020 www econet24 com ecoNET a...

Page 2: ......

Page 3: ...CONNECTION WITH ECOMAX860P3 6 6 3 CONNECTION WITH ECOMAX920 6 7 CONNECTION WITH INTERNET 6 8 LOGGING TO ECONET ACCOUNT 8 8 1 FIRST LOGGING TO ECONET ACCOUNT 8 9 WEBSITE SUPPORT 9 9 1 CURRENT DATA 9 9...

Page 4: ...mentioned above you avoid harmful effects on the environment and human health 3 General informations The internet module enables controller operation remote control on line via Internet User can remot...

Page 5: ...ne COM transmission socket in RJ11 standard which a control panel located inside or outside the controller housing is connected to Using one RJ11 socket in the module requires connecting an additional...

Page 6: ...and 3G USB Port to the ecoLINK2 interface Connect with RJ45 Ethernet Port with Ethernet cable e g with ADSL router switch and modem A socket does not have to be use in case of Wi Fi wireless network...

Page 7: ...e read out and ecoNET24 server connection condition can be checked It is required to save the displayed IP number e g IP 10 1 2 237 This number in a form of http 10 1 2 237 is entered into the address...

Page 8: ...word for an existing account we choose FORGOT PASSWORD and enter your email A password reminder will be sent to your email account 8 1 First logging to ecoNET account In case of first logging user has...

Page 9: ...entering the service password Data history Data archive of selected controller operation parameters Alarms List of controller alarms Schedule Work schedule of the controller and temperature reduction...

Page 10: ...meter value with the slider and confirm with the Save button Exit with modification without saving a new setting is possible by clicking on the symbol 9 4 Data history The Data history tab enables to...

Page 11: ...er can read the fuel consumption in kilograms in a daily cycle every 1 hour or a monthly cycle every 1 day 9 8 Device settings The Device settings tab enables to change the controller installation add...

Page 12: ...300 module has to be connected to power supply 1 Push WPS RESET button during normal module operation 2 Hold this button pressed for at least 10 seconds 3 Release the WPS RESET button 4 A LED indicato...

Page 13: ...his License and to the absence of any warranty and give any other recipients of the Program a copy of this License along with the Program You may charge a fee for the physical act of transferring a co...

Page 14: ...ted by the Free Software Foundation write to the Free Software Foundation we sometimes make exceptions for this Our decision will be guided by the two goals of preserving the free status of all deriva...

Page 15: ...15...

Page 16: ...ul Obornicka 71 62 002 Suchy Las Poland Phone 22 61 811 70 37 biuro kipi pl www kipi pl National Waste Database No 000179569...

Reviews: