10. Specifications
garbou GmbH, Dornaper Strasse 18, 42327 Wuppertal, Germany
Appliance
Outdoor use gas firepit
Model
FR 400 KD 380 Column 400 TF 758 Cube 600
Gas categories:
I3+(28-30/37)
I3B/P(30)
I3B/P(50)
I3B/P(37)
Type of gas
Butane
Propane
Butane, propane or their mixtures
Gas pressure
28 - 30 mbar
37 mbar
30 mbar
50 mbar
37 mbar
Output pressure
from the regualtor
30 mbar
37 mbar
30 mbar
50 mbar
37 mbar
Total heat input
6,5 kW (G30: 473 g/h
G31: 465 g/h)
6,5 kW (473 g/h)
Injector size
1.22 mm main burner
0.25 mm pilot burner
1.10 mm main burner
0.18 mm pilot burner
1.22 mm main burner
0.25 mm pilot burner
The marking, for example 1.22 on the injector, indicates that the size of the injector is 1.22 mm
Countries of destination
DE, AT, CH
Identification code
0063DM7956
Art.-No.
8221400
22
0063
E
N
10. Problem check list
Problem
The pilot flame does not light up
The pilot flame goes out
The burner does not light up
Possible cause
Gas valve is turned off
Gas tank empty
Opening blocked
Air in the system
Loose connections
Dirt at the pilot
Loose connections
Thermocouple is damaged
Leak
Low pressure
Nozzle blocked
Gas valve is turned off
Thermocouple is damaged
The pilot flame burner is bent
The burner is not in the
proper position
Solutions
Turn on the gas valve
Replace the gas cartridge
Clean/replace the opening
Drain the air
Examine all connections
Clean the affected area
Examine all connections
Replace the thermocouple
Examine all connections
Gas cartridge nearly empty, replace it
Clean/replace the nozzle
Turn on the gas valve
Replace the thermocouple
Put the pilot flame burner in the proper position
Position it properly
11. Sale and spare parts
Producer, certificate holder,
service and spare parts:
garbou GmbH
Dornaper Straße 18
D-42327 Wuppertal
[email protected]
Fax: +49 2058 89725-19
Tel.: +49 2058 89725-0
Sales:
BAHAG AG
Gutenbergstr. 21
D-68167 Mannheim
Ver. 10/2022