6. Leakage test
Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas tightness check must
be performed at the installation site due to possible mishandling in shipment or excessive pressure being applied to
the heater.
• Make a soap solution of one part liquid detergent and one part water. The soap solution can be applied with a spray
bottle, brush or rag. Soap bubbles will appear in case of a leak.
• The heater must be checked with a full cylinder.
• Make sure the safety control valve is in the OFF position.
• Turn the gas supply ON.
• In case of a leak, turn off the gas supply. Tighten any leaking fittings, then turn the gas supply on and recheck.
• Never do leak test while smoking.