IMPORTANT SAFETY INSTRUCTIONS

Temperature

Serious Burn Time

120˚F

More than 5 minutes

125˚F

1½ to 2 minutes

130˚F

About 30 seconds

135˚F

About 10 seconds

140˚F

Less than 5 seconds

145˚F

Less than 3 seconds

150˚F

About 1½ seconds

155˚F

About 1 second

WARNING: 

The KINGSPAN TRIBUNE has a 

fitting for a ½” NPT drain plug at the base of the 

tank. This must be fitted with an anti-tamper type 

drain plug to prevent accidental discharge that may 

cause serious scald injuries and/or damage to the 

surrounding property.

Table 1:

 States the relationship between water tempera-

ture and scald risk

1.  READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER.

2.  This water heater must be grounded. Connect only to properly grounded outlet. See “GROUNDING  

 

 

INSTRUCTIONS” found in Section 2.3

3.  Install or locate this water heater only in accordance with the provided installation instructions.

4.  Use this water heater only for its intended use as described in this manual.

5.  Water heaters must be hard wired.

6.  As with any appliance, close supervision is necessary when used by children.

7.  Do not operate this water heater if it is not working properly, or if it has been damaged or dropped.

8.  This water heater should be serviced only by qualified service personnel. Contact nearest authorized    

 

service facility for examination, repair, or adjustment.

SAVE THESE INSTRUCTIONS

DANGER: Very Hot Water can cause serious injury or death 

Ensure that you comply with the instructions contained within this manual and that all components used to set water 

temperature are properly installed and functioning correctly. Consult a qualified installer if you have any problems installing this 

KINGSPAN TRIBUNE unit.

For maximum safety water Thermostatic mixing valves can be purchased that set the water to the faucets to 125˚F or below. 

This is an important consideration especially if your household has children, elderly and disabled persons residing in it. Contact 

a qualified plumber to obtain further information. 

Children, disabled and elderly are at 

highest risk of being scalded.

See instruction manual before 

setting temperature at water heater.

Feel water before bathing or 

showering.

Temperature limiting valves are 

available, see manual

WARNING

When using electrical appliances, basic safety precautions to reduce the risk of fire, electric shock or injury to persons 

should be followed including 

Summary of Contents for Tribune

Page 1: ...IMPORTANT NOTE TO THE INSTALLER Read these instructions before commencing installation Installation Manual For Kingspan Tribune USA Issue 4 Sept 2010 Part No BOOKSTAINULT Page 1 of 12 Tribune ...

Page 2: ...ate this water heater if it is not working properly or if it has been damaged or dropped 8 This water heater should be serviced only by qualified service personnel Contact nearest authorized service facility for examination repair or adjustment SAVE THESE INSTRUCTIONS DANGER Very Hot Water can cause serious injury or death Ensure that you comply with the instructions contained within this manual a...

Page 3: ...t maximum of 2 The pan should be connected to drain by a bore drain Consult a certified plumber for more information The KINGSPAN TRIBUNE should be located near to a drain to allow the drainage of water during maintenance and as an outlet for the safety equipment located on the unit The KINGSPAN TRIBUNE tank can supply outlets above it or at some distance from it Site the unit to minimise dead leg...

Page 4: ...s allows a variety of heat sources to be used In the single coil configuration this can be connected to a boiler or solar circuit Twin coil tanks the lower coil is connected to a solar circuit and the top coil to a boiler system Figure 1 shows a schematic of the tank configuration Page 4 of 12 Figure 1 Single and Twin coil configurations ...

Page 5: ...d water system meaning that thermal expansion may cause a pressure build up within your hot water tank In such a case an expansion tank must be fitted to allow for any excess pressure caused by thermal expansion Please see figure 2 for reference Water pressure If the incoming water pressure is over 80 PSI a pressure reducing valve Water pressure regulator must be fitted This is to be located on th...

Page 6: ...e The hot water tank has a NPT female connection to accommodate this apparatus in the top of the tank CAUTION To reduce the risk of excessive pressures and temperatures in this water heater install temperature and pressure protective equipment required by local codes but no less than a combination pressure valve certified as meeting the requirements for Relief Valves and Automatic Gas Shutoff devi...

Page 7: ...r the immersion heater current load The unit must be grounded to a properly installed ground circuit using an appropriate field terminal Check the immersion heaters are 240V and rated at 4500W this should be stated on the case Figure 3 shows the layout and wiring schematic of the heating element To access the wiring terminals firstly remove the temperature dial by gently pulling of the dial comple...

Page 8: ...pen every other hot faucet in turn to purge all remaining air 3 1 FILLING If the tank is to be heated by an indirect boiler consult the boiler manufacturers commissioning instructions and fill the primary circuit accordingly Two port valves and tank thermostats may need to be used to control input into the KINGSPAN TRIBUNE unit 3 2 INDIRECT UNITS During heat up there should have been no sign of wa...

Page 9: ...3 4 INSTALLATION CHECKLIST FLOW CHART Page 9 of 12 Figure 4 Check list of installation steps ...

Page 10: ...me as the annual boiler or solar system service 1 Lift the lever on the expansion relief valve on the inlet control set and allow water to flow for 5 seconds Release and make sure it resets correctly Repeat with the pressure temperature relief valve In both cases check that the discharge pipe work is carrying the water away adequately If not check for blockages etc and clear WARNING THE WATER DISC...

Page 11: ...er than by kingspan It has not been misused tampered with or subjected to neglect It has only been used for the storage of potable water It has not been subjected to frost damage The unit has been serviced annually The guarantee period starts from the date of purchase and no registration is required The guarantee is not transferable and rests with the original householder The system is fed from a ...