background image

20 

User Instruction Manual

Kingspan SafePro 2 

Anchor and Cable System

15.0 Pre-Use & In Use Checks

15.1 Personal Protective Equipment

Equipment should be certified and marked to the appropriate 
national standard, always refer to the manufactures instructions 
for use.
Always wear a full body harness. Examine harnesses, lanyards, 
self-retracting lifelines or controlled rate descent devices in 
accordance with their manufacturer’s instructions to ascertain if 
they are serviceable. If in doubt do not use them. If these items 
have been subjected to a fall they must be serviced or discarded. 
When not in use these articles need to be stored in a clean, cool, 
dry area, free from chemical fumes or corrosive elements. Direct 
sunlight, heat, steam, undue vibration and sharp implements 
must also be avoided. Preferably, fall arrest equipment like this 
should, when not required for use, be kept in dedicated cabinets 
which permit adequate ventilation.

15.2 Kingspan SafePro 2 Cable System Grab

Check the slider before use for any damage. Any damage should 
be reported to the Installer and the device removed from service 
until it has been inspected. If a fall has occurred on the slider, 
the device should be removed from service until it has been 
inspected.
The slider can only be put back in to service after it has been 
approved in writing by a Kingspan certified Installer.
Kingspan recommend that only the supplied Kingspan carabiner 
be used with the slider.
Before attaching to the SafePro 2 Cable system:
1. Check that the slot does not exceed 6.1mm.
2. Check that the slider cannot be opened when the carabiner is 
attached to the slider.

15.3 Compatibility of Components

Prior to accessing the system the user should always inspect the 
system label and certificate in order to confirm:
–   The correct user equipment is being used (including lanyard 

length)

–  The maximum number of users is not exceeded
–   The system certification is valid. The system should be certified 

yearly. If this has not been done the user should not use the 
system

–    Check that the ground clearance is still the same as detailed 

on the system label and that there is no risk of collision in the 
event of a fall – including swing fall (pendulum fall) hazards.

If possible before attaching to the system, carry out a visual 
inspection. Check that there are no obvious signs of damage to 
the system, such as breaks, kinks or excessive sag in the cable 
or damaged brackets. Turn the disc attached to the tensioner. If 
the disk does not turn, contact your Installer for advice. Check 
the legibility of all markings on any part of the system and the 
users PPE.
If any of the above is questionable do not use the System and 
report to a Certified Kingspan Installer.
Only use connectors that are suitable to each application. Ensure 
all connections are compatible in size, shape and strength.
Do not use equipment that is not compatible. Contact Kingspan 
if you have any questions about compatibility.

3M™ DBI-SALA

®

 RoofSafe Anchor and Cable System

Pre-Use & In Use Checks
Section 15.0

20

15.1  Personal Protective Equipment

Equipment should be certified and marked to the appropriate national standard, always refer to the manufactures instructions for use. 
Always wear a full body harness. Examine harnesses, lanyards, self-retracting lifelines or controlled rate descent devices in accordance 
with their manufacturer’s instructions to ascertain if they are serviceable. If in doubt do not use them. If these items have been subjected 
to a fall they must be serviced or discarded. When not in use these articles need to be stored in a clean, cool, dry area, free from chemical 
fumes or corrosive elements. Direct sunlight, heat, steam, undue vibration and sharp implements must also be avoided. Preferably, fall 
arrest equipment like this should, when not required for use, be kept in dedicated cabinets which permit adequate ventilation.

15.2  3M™ DBI-SALA

®

 RoofSafe Cable System Grab

Check the UniGrab before use for any damage. Any damage should be reported to the Installer and the device removed from service 
until it has been inspected. If a fall has occurred on the UniGrab, the device should be removed from service until it has been inspected.

The UniGrab can only be put back in to service after it has been approved in writing by a 3M Fall Protection certified Installer

3M Fall Protection recommend that only the supplied 3M Fall Protection carabiner be used with the UniGrab.

Before attaching to the 3M DBI-SALA RoofSafe Cable system:

1.  Check that the slot does not exceed 6.1 mm.

2.  

Check that the UniGrab cannot be opened when the carabiner is attached to the UniGrab.

4.5 mm to 6.1 mm

If in doubt.

Ask.

UniGrab

15.3  Compatibility of Components

Prior to accessing the system the user should always inspect the system label and certificate in order to confirm:

•  

The correct user equipment is being used (including lanyard length)

•  

The maximum number of users is not exceeded

•  

The system certification is valid. The system should be certified yearly. If this has not been done the user should not use the system

•  

Check that the ground clearance is still the same as detailed on the system label and that there is no risk of collision in the event  
of a fall – including swing fall (pendulum fall) hazards.

If possible before attaching to the system, carry out a visual inspection. Check that there are no obvious signs of damage to the system, 
such as breaks, kinks or excessive sag in the cable or damaged brackets. Turn the disc attached to the tensioner. If the disk does not 
turn, contact your Installer for advice. Check the legibility of all markings on any part of the system and the users PPE.

If any of the above is questionable do not use the System and report to a Certified 3M Fall Protection Installer.

Only use connectors that are suitable to each application. Ensure all connections are compatible in size, shape and strength.  
Do not use equipment that is not compatible. Contact 3M Fall Protection if you have any questions about compatibility.

Form No: 5903917   Rev: D

Slider

If in doubt. Ask.

4.5mm to 6.1mm

Summary of Contents for SafePro 2

Page 1: ...Kingspan SafePro 2 Anchor and Cable System User Instruction Manual Fabrications Safety Lighting solutions UK Ireland...

Page 2: ...Maintenance Check List Anchor 14 10 0 Foreword Cable 15 11 0 The SafePro 2 Cable System 16 11 1 The Kingspan SafePro 2 Cable System 16 11 2 Positioning the SafePro 2 Cable System 16 Contents 12 0 Syst...

Page 3: ...n certified Installer or competent persons trained by Kingspan or Kingspan s representative and must be in accordance with Kingspan s technical instructions and all prevailing national standards All u...

Page 4: ...gid anchor The Anchors c arrest and work restraint applications The Anchors can be installed on standing seam bituminous and PVC membrane composite built up and roofing systems Both Anchors allow the...

Page 5: ...all 3M DBI SALA RoofSafe Anchor and Cable System The RoofSafe Anchor Section 2 0 2 2 Positioning of the 3M DBI SALA RoofSafe Anchor When positioning the 3M DBI SALA RoofSafe Anchor System there are tw...

Page 6: ...all the tools and information required to successfully install and test the product Included in this manual is a checklist of the minimum amount of information that should be supplied by the installe...

Page 7: ...fixings The Anchor s must not be used as a lifting system Do not use the Anchor for equipment tie back Never exceed the recommended number of users on the Anchor See label on product or system tag Ne...

Page 8: ...s bitumen cement chloride paint or aggressive cleaning fluids Stainless Steel parts are particularly susceptible to pitting corrosion from chlorine so avoid exposure in this type of environment If the...

Page 9: ...implements must also be avoided Preferably fall arrest equipment like this should when not required for use be kept in dedicated cabinets which permit adequate ventilation 6 0 Pre Use In Use Checks 6...

Page 10: ...r cross members that are not shaped in a way that can capture the gate of the hook 3M DBI SALA RoofSafe Anchor and Cable System Pre Use In Use Checks Section 6 0 10 6 3 Compatibility of Components If...

Page 11: ...g lanyard to the rear D ring of the harness This prevents the lanyard getting in the way during use Always ensure make compatible connection only Always ensure that the locking mechanism of the carabi...

Page 12: ...gistration card Recorded and indicated the minimum ground clearance Provided the contact details of Kingspan Provided the contact details of the Installation company The maximum number of users permit...

Page 13: ...minous Membrane Roof Composite Built Up Roof PVC Membrane Roof Form No 5903917 Rev D 3M DBI SALA RoofSafe Anchor and Cable System Typical Anchors Section 8 0 13 Standing Seam Roof Anchor Bituminous Me...

Page 14: ...rectly tightened Use Torque Wrench as required Proof load test concrete fixings to 6kN Clean system as necessary Check Attachment Devices operate correctly Cable Systems Check cable condition for fret...

Page 15: ...should be conducted by a Kingspan certified Installer or competent persons trained by Kingspan or Kingspan s representative and must be in accordance with the Kingspan s technical instructions and all...

Page 16: ...sealed around the Anchors for true weather proofing SpiraTech Anchor Single Point Tip Over Anchor Can be used as a single point Anchor for up to two users CE Only Can be used as a single point Anchor...

Page 17: ...he product Included in this manual is a checklist of the minimum amount of information that should be supplied by the installer following the installation of your Anchor s 12 3 Fixings It is imperativ...

Page 18: ...sting the Anchor and fixings The System must not be used for lifting Do not use the system for equipment tie back Never exceed the recommended number of users on the system See label on product or sys...

Page 19: ...e system with acids bitumen cement chloride paint or aggressive cleaning fluids Stainless Steel parts are particularly susceptible to pitting corrosion from chlorine so avoid exposure in this type of...

Page 20: ...s kinks or excessive sag in the cable or damaged brackets Turn the disc attached to the tensioner If the disk does not turn contact your Installer for advice Check the legibility of all markings on an...

Page 21: ...ty If necessary the user should use other safety equipment such as a twin tailed lanyard to facilitate safe access to the attachment area 16 3 Attaching to the System The slider is designed in such a...

Page 22: ...point of the UniGrab should be facing towards the side you want to walk on 16 4 Working on both sides of the 3M Fall Protection System To remove the UniGrab reverse the procedure on page 9 If you wish...

Page 23: ...the installation A unique identification number The number and length of systems The maximum number of users per span and per system The length and type of lanyards The installation date The date of...

Page 24: ...NOTES 1 MATERIAL 031 004 0 8mm 0 1mm ALUMINUM 5005 2 FINISH ANODIZED SCREEN PRINTED BLACK BLUE Pantone 2748 LOW TEMPERATURE BAKED USE THE CURRENT REVISION OF FILE 7241184 ai FOR LABE L GEOMETRYAND ART...

Page 25: ...nents SYSTEMEYE PIN SafePro 2 System Eye Pin CORNER90 8mm 90 Corner TOGGLE8mm 8mm Hex Swage Toggle TENSIONER8mm 8mm 0 8 kN Hex Swage Tensioner CORNER45 8mm 45 Corner SLIDER CAR8mm 8mm UniGrab Carabine...

Page 26: ...rectly tightened Use Torque Wrench as required Proof load test concrete fixings to 6kN Clean system as necessary Check Attachment Devices operate correctly Cable Systems Check cable condition for fret...

Page 27: ...n to deal with such emergencies cannot be overemphasized Such a plan includes consideration of rescue equipment personnel and training as necessary It is not acceptable just to rely on the emergency s...

Page 28: ...r markets please contact your local sales representative or visit www kingspanpanels com Care has been taken to ensure that the contents of this publication are accurate but Kingspan Limited and its s...

Reviews: