background image

19 

User Instruction Manual

Kingspan SafePro 2 

Anchor and Cable System

14.0 Inspection, Maintenance,  

Servicing & Warranty

14.1 Inspection and General Maintenance

The Kingspan SafePro 2 Cable System has been designed 
to be used under a variety of conditions. It uses high-grade 
components that are corrosion resistant. However, the 
System’s working life depends on factors such as correct care 
and maintenance and the environment in which the system is 
installed. Before each occasion of use a visual check must be 
conducted to ensure the Anchor is fit for purpose.
If the System is deformed in a way which is uncharacteristic 
of the System you should not use it. Report the faults to the 
Kingspan Certified Installer and schedule a maintenance visit.
DO NOT attempt to repair the System yourself, as this may 
invalidate performance warranties and put personnel in danger.
The SafePro 2 Cable System is virtually maintenance free 
dependent on environment. Occasionally the System may 
need cleaning. This should be done with a soft brush, warm 
water and a mild detergent. Ensure the parts are thoroughly 
rinsed with plenty of clean water. Although highly resistant to 
chemicals and environmental conditions, take all precautions to 
avoid contaminating the system with acids, bitumen, cement, 
chloride, paint or aggressive cleaning fluids.
Stainless Steel parts are particularly susceptible to pitting 
corrosion from chlorine, so avoid exposure in this type of 
environment. If the system is likely to be contaminated, please 
contact your Kingspan Certified Installer or Kingspan for advice.

14.2 Servicing

In accordance with current national standards and Kingspan’s 
recommendations, an Anchor that is in regular use should be 
inspected at least once a year by an Certified Kingspan Installer. 
In very high use applications or aggressive environments the 
servicing interval should be more frequent as determined by the 
installer. The System has many unique features, therefore only 
Certified Kingspan Installers who have been trained and certified 
should inspect this product.
A maintenance checklist is provided to our Approved Installers 
to use during annual inspections. Please see Section 20.0 in this 
manual.
If the System has sustained a fall arrest impact, has been 
damaged, or is defective in any way, it must be immediately 
categorised as unfit for use. The use of the system must be 
discontinued, and servicing should be arranged as soon as 
possible. All servicing requirements should be directed to 
Kingspan or their Certified Installer.

14.3 Warranty

Full details of the warranty terms and exclusions are available 
under the SafePro 2 Cable System warranty, which is available as 
a separate document.

Summary of Contents for SafePro 2

Page 1: ...Kingspan SafePro 2 Anchor and Cable System User Instruction Manual Fabrications Safety Lighting solutions UK Ireland...

Page 2: ...Maintenance Check List Anchor 14 10 0 Foreword Cable 15 11 0 The SafePro 2 Cable System 16 11 1 The Kingspan SafePro 2 Cable System 16 11 2 Positioning the SafePro 2 Cable System 16 Contents 12 0 Syst...

Page 3: ...n certified Installer or competent persons trained by Kingspan or Kingspan s representative and must be in accordance with Kingspan s technical instructions and all prevailing national standards All u...

Page 4: ...gid anchor The Anchors c arrest and work restraint applications The Anchors can be installed on standing seam bituminous and PVC membrane composite built up and roofing systems Both Anchors allow the...

Page 5: ...all 3M DBI SALA RoofSafe Anchor and Cable System The RoofSafe Anchor Section 2 0 2 2 Positioning of the 3M DBI SALA RoofSafe Anchor When positioning the 3M DBI SALA RoofSafe Anchor System there are tw...

Page 6: ...all the tools and information required to successfully install and test the product Included in this manual is a checklist of the minimum amount of information that should be supplied by the installe...

Page 7: ...fixings The Anchor s must not be used as a lifting system Do not use the Anchor for equipment tie back Never exceed the recommended number of users on the Anchor See label on product or system tag Ne...

Page 8: ...s bitumen cement chloride paint or aggressive cleaning fluids Stainless Steel parts are particularly susceptible to pitting corrosion from chlorine so avoid exposure in this type of environment If the...

Page 9: ...implements must also be avoided Preferably fall arrest equipment like this should when not required for use be kept in dedicated cabinets which permit adequate ventilation 6 0 Pre Use In Use Checks 6...

Page 10: ...r cross members that are not shaped in a way that can capture the gate of the hook 3M DBI SALA RoofSafe Anchor and Cable System Pre Use In Use Checks Section 6 0 10 6 3 Compatibility of Components If...

Page 11: ...g lanyard to the rear D ring of the harness This prevents the lanyard getting in the way during use Always ensure make compatible connection only Always ensure that the locking mechanism of the carabi...

Page 12: ...gistration card Recorded and indicated the minimum ground clearance Provided the contact details of Kingspan Provided the contact details of the Installation company The maximum number of users permit...

Page 13: ...minous Membrane Roof Composite Built Up Roof PVC Membrane Roof Form No 5903917 Rev D 3M DBI SALA RoofSafe Anchor and Cable System Typical Anchors Section 8 0 13 Standing Seam Roof Anchor Bituminous Me...

Page 14: ...rectly tightened Use Torque Wrench as required Proof load test concrete fixings to 6kN Clean system as necessary Check Attachment Devices operate correctly Cable Systems Check cable condition for fret...

Page 15: ...should be conducted by a Kingspan certified Installer or competent persons trained by Kingspan or Kingspan s representative and must be in accordance with the Kingspan s technical instructions and all...

Page 16: ...sealed around the Anchors for true weather proofing SpiraTech Anchor Single Point Tip Over Anchor Can be used as a single point Anchor for up to two users CE Only Can be used as a single point Anchor...

Page 17: ...he product Included in this manual is a checklist of the minimum amount of information that should be supplied by the installer following the installation of your Anchor s 12 3 Fixings It is imperativ...

Page 18: ...sting the Anchor and fixings The System must not be used for lifting Do not use the system for equipment tie back Never exceed the recommended number of users on the system See label on product or sys...

Page 19: ...e system with acids bitumen cement chloride paint or aggressive cleaning fluids Stainless Steel parts are particularly susceptible to pitting corrosion from chlorine so avoid exposure in this type of...

Page 20: ...s kinks or excessive sag in the cable or damaged brackets Turn the disc attached to the tensioner If the disk does not turn contact your Installer for advice Check the legibility of all markings on an...

Page 21: ...ty If necessary the user should use other safety equipment such as a twin tailed lanyard to facilitate safe access to the attachment area 16 3 Attaching to the System The slider is designed in such a...

Page 22: ...point of the UniGrab should be facing towards the side you want to walk on 16 4 Working on both sides of the 3M Fall Protection System To remove the UniGrab reverse the procedure on page 9 If you wish...

Page 23: ...the installation A unique identification number The number and length of systems The maximum number of users per span and per system The length and type of lanyards The installation date The date of...

Page 24: ...NOTES 1 MATERIAL 031 004 0 8mm 0 1mm ALUMINUM 5005 2 FINISH ANODIZED SCREEN PRINTED BLACK BLUE Pantone 2748 LOW TEMPERATURE BAKED USE THE CURRENT REVISION OF FILE 7241184 ai FOR LABE L GEOMETRYAND ART...

Page 25: ...nents SYSTEMEYE PIN SafePro 2 System Eye Pin CORNER90 8mm 90 Corner TOGGLE8mm 8mm Hex Swage Toggle TENSIONER8mm 8mm 0 8 kN Hex Swage Tensioner CORNER45 8mm 45 Corner SLIDER CAR8mm 8mm UniGrab Carabine...

Page 26: ...rectly tightened Use Torque Wrench as required Proof load test concrete fixings to 6kN Clean system as necessary Check Attachment Devices operate correctly Cable Systems Check cable condition for fret...

Page 27: ...n to deal with such emergencies cannot be overemphasized Such a plan includes consideration of rescue equipment personnel and training as necessary It is not acceptable just to rely on the emergency s...

Page 28: ...r markets please contact your local sales representative or visit www kingspanpanels com Care has been taken to ensure that the contents of this publication are accurate but Kingspan Limited and its s...

Reviews: