6
Locating your Appliance
(above or below grade)
Installing with Slope Top Vent
Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1m). When you install
your fireplace as in position ‘B’, ‘D’ or ‘E’, a minimum of 6 inches (153mm) clearance must be maintained from the perpendicular wall and the
front of the appliance.
A - Flat on a wall
D - As a room divider
B - Across the corner
E - Flat on wall corner
C - As an island
F - Exterior wall
7"
4"
16.75"
16.25"
42"
36"
36"
6"
16.75"