Conversion Kit Instructions
– PART A
Kit Number
Description
Pilot Orifice
Burner Orifice
Brass (1000-255)
Brass Nipple
Air Shutter
Hi/Lo Regulator
3622-CKLP
LP Conversion
-Millivolt-
1001-P167SI
#30
(977.167)
#54
1000-P201VE
3/8”
1001-P202SI
(0.907.202)
3622-CKNG
NG Conversion
-Millivolt-
1001-P165SI
#51
(977.165)
#43
1000-P201VE
3/16
”
1001-P201SI
(0.907.201)
3622RB-CKLP
LP Conversion
-Millivolt-
1001-P167SI
#30
(977.167)
1.25mm
1000-P201VE
5/16”
1001-P202SI
(0.907.202)
3622RB-CKNG
NG Conversion
-Millivolt-
1001-P165SI
#51
(977.165)
#47
1000-P201VE
1/16”
1001-P201SI
(0.907.201)
3622 -CKLPI
LP Conversion
-IPI -
1001-P168SI
#35
(977.168)
#54
1000-P201VE
3/8”
1002-P014SI
(0.907.014)
3622 -CKNGI
NG Conversion
- IPI -
1001-P166SI
#62
(977.166)
#43
1000-P201VE
3/16”
1002-P016SI
(0.907.016)
3622RB-CKLPI
LP Conversion
-IPI -
1001-P168SI
#35
(977.168)
1.25mm
1000-P201VE
5/16”
1002-P014SI
(0.907.014)
3622RB-CKNGI
NG Conversion
- IPI -
1001-P166SI
#62
(977.166)
#47
1000-P201VE
1/16”
1002-P016SI
(0.907.016)
Refer to “
Gas Specifications Chart
” for inlet pressures and input ratings. Clock meter to verify input rate. Place conversion label
as close to converted gas control as possible. Refer to lighting instructions to verify the normal operating sequence of the ignition
system. IMPORTANT: Always check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK
TESTING.
⚠
-CAUTION-
Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all
electrical connections to the appliance. Allow the appliance to cool to room temperature. Note
that the pilot assembly may be hot in an intermittent or standing-pilot system
—even if the main
burner was never on. Exercise caution when working within the area.
-ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN-