ZCV3622 / ZCVRB3622
Framing Dimensions
Determine whether face of fireplace will be:
Flush with finished wall (e.g., for surround, cultured stone or other non combustible covering).
Flush with framing (to be covered with concrete board for a Flat Wall appearance).
Refer to Nailing Tab Guide section also.
Framing for Horizontal Vent
Termination
(See
Installation of Side
Wall Venting
Section)
Vertical
Venting MUST maintain 1” clearance to combustibles.
These structures are not load bearing.
*For Propane Horizontal installations the venting must be an additional one foot above
the minimum vertical rise off the flue before going horizontal.
NOTE:
Framing is shown Flush with Face of Fireplace (17-1/2
” Deep). See
Nailing Tab Guide
section.
33
” MIN for NG
45
” MIN for LP
Plus Rise of 1/4”
Per Foot*
RIGHT SIDE
14