ZCV39 / ZCV42
Z46FK Fan Kit Installation
The fan can be installed through
the side of the fireplace.
If fireplace is already installed, the
burner pan must be removed to
install the fan (See Burner System
Removal section).
To install the fan from the side of
the unit,
remove the two screws in
the Fan Access Cover on the left side
of the fireplace. Bend the cover up
and pull bottom tab down. Insert fan through opening as shown.
Mount fan on tabs in bottom of fireplace. Connect fan as per wiring diagram below. Replace all components.
Fan Speed Control
is located outside of fireplace.
Thermodisc
is
Located under Burner pan.
⚠
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three prong (grounding) plug for your protection against
shock hazard and should be plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from this.
Before Servicing
1. Ensure all power supply is shut off.
2. Label all wires prior to disconnecting when servicing control. Wiring errors can cause
improper and dangerous operation.
3. For fan servicing: Vacuum and clean lint/dirt build-up on the fan blades and motor.
4. When resealing the Burner Pan, use Mill Pac.
Fan Speed
Control
(Located
Outside of
Fireplace)
Thermodisc
Located under Burner pan
NOTE: Do not allow cords or wires to come
into contact with the firebox or the underside
of the burner pan.
Fan Mount Tabs
37