Removing Burner System / Access Cover
If Fireplace has been installed with optional CVCK (Clean View
Circulating Kit) to service fan system or burner system controls,
the access cover and burner system will have to be removed
Access cover removal
1. Remove door, logs, brick panels, false bottom, burner grate
and burner from firebox.
2. Lift false bottom up (on applicable units only) from alignment
pins and remove. Burner grate (on applicable units only) is
fastened by 2 screws one right and left of grate, remove
screws and take out grate. Remove burner by loosening burn-
er retainer tab screws and slide burner left off orifice. Access
cover is now exposed for removal.
3. Remove 10 screws holding access cover in place. Push down
on one corner of access cover to break seal of cover, once
loose cover can be slid under firebox bottom to expose gas
connection.
Removing Burner System
1. Disconnect gas line connection at burner system through
access cover opening.
2. Remove extension knobs and wiring from face of gas valve.
3. Undo screws holding back log holder (on applicable units
only) and remove. Remove screws from perimeter of burner
system pan, lift pan at one back corner and rotate pan up
from back of firebox. Make sure when tilting up and removing
burner system, that all fan and valve control wiring is discon-
nected. To re-install access cover / burner system remove old
Mil Pac sealant and apply new sealant. After new sealant is
applied reverse removal procedure to re-install parts.
* Caution high temperature sealant has been applied to access
cover and burner system pan. New sealant will have to be
applied when re-installing access cover and burner stem to
maintain the integrity of sealed combustion chamber. Mil Pac
part #840099 or Kingsman part # 1000-150MP sealant can
be purchased from your Kingsman retailer or distributor.
Warning: Before starting removal of parts turn off
gas supply, disconnect 110 volts to fan system and
disconnect 110 volts to electronic ignition burner system
if applicable.
Warning: All work should be performed by a
qualified and certified technician.
Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
15
Summary of Contents for HBZDV4740
Page 23: ...Gas Conversion for Modulator PART C WARNING WARNING 23 ...
Page 26: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 26 ...
Page 27: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 27 ...
Page 28: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 28 ...