Framing for your Gas Fireplace
Framing Specifications
1. Cold climate installation recommendation: When installing this fire-
place against non insulated exterior wall or chase, it is recom -
mended that the outer walls be insulated to conform to applicable
insulation codes. Drywall must be installed over insulation to prevent
contact of insulation and unit.
2. Choose fireplace location and frame in accordance with the fireplace
framing dimensions specified (See Framing Diagrams). Bend nailing
tabs forward on left and right of unit and place fireplace into framed
enclosure. This allows for 1/2” in front of framing tabs for finishing
materials.
3. Drywall or other material can extend flush with the appliance on the
bottom, sides and top of fireplace. (louvered models only)
HBZDV47 Louvered
HBZDV47 WITH CVCK (CLEAN VIEW CIRCULATING KIT)
4. When installing horizontal with a 90 degree bend maintain a mini-
mum of two and a half (2.5”) inches above the bend in enclo-
sures,insulation sleeve is required. If greater than six and a half (6.5”)
an insulation sleeve is not required.
5. For HBZDV with louvers combustible floor can raise 1” above the bot-
tom of the fireplace. For HBZDV with CVCK (Clean view Circulating
Kit) floor or hearth can raise 7” above the bottom of the fireplace
with portions being combustible and non combustible. See drawing
Below.
6. When installing MQHB47SWCC wall surround, the fireplace must be
raised a minimum of 3 1/2” above the finished floor, to accommodate
the wall surround. When installing MQHB47SWCV wall surround the
fireplace must be raised 2 3/4” above the finished floor. The fireplace
may be raised higher but the 60” clearance measured from the bot-
tom of the fireplace to the ceiling must be maintained at all times. (i.e.
For an 8 ft. ceiling the unit can be raised only 36 inches.)
8
21
⁄
32
" DIA.
11"
11"
TOP VIEW
For
Propane Horizontal Installations
the venting must be a minimum of one foot vertical off the flue before the elbow on any
horizontal runs of one foot or greater. This allows for cleaner combustion and greatly reduces carboning and cleaning of glass.
9
Summary of Contents for HBZDV4740
Page 23: ...Gas Conversion for Modulator PART C WARNING WARNING 23 ...
Page 26: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 26 ...
Page 27: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 27 ...
Page 28: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 28 ...