GAS SPECIFICATIONS
OPERATING AND MAINTENANCE INSTRUCTIONS
This gas appliance should be installed by a qualified installer in accordance with local building codes and with
current CAN/CGA-B149.1 or .2 installation codes for Gas Burning Appliances and Equipment.
FOR SAFE INSTALLATION AND OPERATION NOTE THE FOLLOWING:
This appliance gives off high temperatures and should be located out of heavy traffic areas and away from furniture
and draperies.
Children and adults should be alerted to the hazards of high surface temperatures of this appliance and should stay
away to avoid burns or ignition of clothing.
Control compartments, burners and air passages in this appliance should be kept clean and free of dust and lint. Make
sure that the gas valve and pilot light are turned off before you attempt to clean this unit.
7
WARNING: WHEN PURGING THE GAS LINE, THE GLASS
FRONT MUST BE REMOVED.
FUEL
GAS
MAXIMUM INPUT MAXIMUM OUTPUT
CONTROL
(BTU)
(BTU)
HIGH
LOW
HIGH
NATURAL GAS
MILLIVOLT
32,000
25,000
23,700
PROPANE GAS
MILLIVOLT
32,000
22,500
24,320
GAS INLET SIZE
1/2”(WR)
GAS INLET SIZE
3/8”(SIT)
MAXIMUN EFFICIENCY (FAN ON)
(78 NG), (80% LP)
NATURAL GAS
4.5
7
9
PROPANE GAS
10.8
11
12
GAS SUPPLY
MINIMUM
NORMAL
MAXIMUM
PRESSURE
(INCHES WATER COLUMN)
UNIT TYPE
MANIFOLD PRESSURE
(INCHES WATER COLUMN)
NATURAL GAS
3.5
PROPANE GAS
10.5
UNIT TYPE
Orifice Size /
Air
Shutter Setting
NATURAL GAS (0-4500 FT)
(35) Air Shutter.102”
PROPANE GAS (0-4500 FT)
(51) Air Shutter .437”
f i r e - p a r t s . c o m