12
FV/FDV 5000 OPTIONAL FAN KIT INSTALLATION
Caution: Do not connect any wires from the fan assembly to the Gas Valve.
NOTE: FOR EASE OF INSTALLATION THE FAN KIT SHOULD BE INSTALLED BEFORE THE STOVE IS
PUT IN ITS FINAL POSITION.
AUTOMATIC ON/OFF THERMOSTAT CONTROLLED FAN KIT (Part #F35FK)
1. Open Access Door where the piezo-igniter is located and install the variable speed control in the hole provided opposite the
piezo-igniter.
2. Locate the two fan mounting bracket screws in the rear of the unit as shown in the above diagram Fig.1, remove one of the screws
and loosen the other screw. Place the fan mounting bracket in position and tighten screws.
3. Locate the two fan mounting screws as shown in the diagram and place the key holes on the fan over the mounting screws and drop
into position.
4. Connect the wires to the sensor and variable speed control as shown in the diagram. Connect the fan extension cord to 110volt power.
5. Turn the variable speed control to the on position (clockwise). NOTE: The stove must now be installed and gas line attached before
proceeding.
6. Turn the stove on. Once the sensor unit reaches operating temperature (in approximately 10 to 15 minutes) the fan will turn on. The
fan can be switched off, if desired by turning the switch fully counter-clockwise.
7. Once the fan has started to turn it may be desirable to adjust the minimum fan speed. Tilt the control panel forward to access the
rear of the variable speed switch, turn the variable speed switch to its minimum setting (fully clockwise). Use the set screw on the
side of the variable speed control to increase or decrease the minimum fan speed. (It may be desirable to lower minimum fan speed
to decrease the sound level created by the fan.) Reinstall the control panel.