background image

If Serial Number is BETWEEN 4468-4740 
SYSTEM #2 New Top Convertible SIT system:
5000 - VBLPSI

LP SIT BURNER ASSEMBLY C/W VALVE

5000 - VBNGSI

NG SIT BURNER ASSEMBLY C/W VALVE

1000-P136WR

Thermopile GOAI-524

1001-P069SI

Electrode Sparker 915.069 TC SIT

1001-P216SI

Thermocouple 290.216 TC SIT

1001-P165SI

Orifice Pilot NG 977.165 TC SIT

1001-P167SI

Orifice Pilot LP 977.167 TC SIT

1001-P508SI

HT Cable 16

1001-P633SI

Valve Nova LP Hi/Lo   0820633

1001-P634SI

Valve Nova NG Hi/Lo  0820634

1001-P713SI

Pilot Burner LP 199.713 TC SIT

1001-P714SI

Pilot Burner NG 199.714 TC SIT

If Serial Number is GRETAER than 4740 only 
SYSTEM #3 New SIT TC True Millivolt Vented :
5000 - VBLPSI

LP SIT BURNER ASSEMBLY C/W VALVE

5000 - VBNGSI

NG SIT BURNER ASSEMBLY C/W VALVE

1000-P136WR

Thermopile GOAI-524

1001-P069SI

Electrode Sparker 915.069 TC SIT

1001-P165SI

Orifice Pilot NG 977.165 TC SIT

1001-P167SI

Orifice Pilot LP 977.167 TC SIT

1001-P639SI

Valve Nova LP Hi/Lo   0820639 True MV

1001-P640SI

Valve Nova NG Hi/Lo  0820640 True MV

1001-P745SI

Pilot Burner LP 199.745 TC TM

1001-P746SI

Pilot Burner NG 199.746 TC TM

16

f i r e - p a r t s . c o m

Summary of Contents for FV5000

Page 1: ...Co Inc 2340 Logan Ave Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Read this complete manual before beginning installation These instructions must be kept with the unit for future reference FOR Y...

Page 2: ...ever due to the high temperature silicone components the paint will cure when heat is applied to the appliance as it is first used The following information applies to the curing process to get the pa...

Page 3: ...intenance instructions 7 General glass information 8 Log assembly 9 Log placement 10 11 Optional fan kit installation 12 Millivolt system lighting burner control 13 Vent installation 14 Accessory list...

Page 4: ...temperatures and should be located out of heavy traffic areas and away from furniture and draperies 2 Children and adults should be alerted to the hazards of the high surface temperatures of this appl...

Page 5: ...tockings or decorations be hung from it 9 Under no circumstances should any solid fuels wood paper be used in this appliance 10 For safe operation purge gas line with glass door removed to assure a co...

Page 6: ...of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pres...

Page 7: ...ts burners and air passages in this appliance should be kept clean and free of dust and lint Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit 7 WARNING...

Page 8: ...reas This appliance should not be used as drying rack for clothing nor should Christmas stockings or decorations be hung near it Under no circumstances should any solid fuels wood paper cardboard coal...

Page 9: ...imately 1 8 to all four sides of frame and insert glass with new gasket Frame should be placed on a flat surface with a small amount of weight pressing glass into sealant Let dry approximately 15 to 2...

Page 10: ...log Step 2 Break glowing embers into thumbnail size Place glowing embers evenly on to the front burner Do not go over the grate Step 3 Place front log over front burner with the left right sides agai...

Page 11: ...ded Bark should be to the outside Step 6 Place left crossover log into the slots that are provided Bark should be to the outside Step 7 Purge lines and test pilot operation Step 8 Replace glass door L...

Page 12: ...to position 4 Connect the wires to the sensor and variable speed control as shown in the diagram Connect the fan extension cord to 110volt power 5 Turn the variable speed control to the on position cl...

Page 13: ...push knob in for one 1 minute Release knob Pilot should remain lit If it goes out repeat steps 2 through 5 until pilot remains lit If knob does not pop up when released stop and immediately call your...

Page 14: ...hes or larger Four 4 inch single wall or B Vent liquid fuel gas chimney or Flex Gas Liner may be used to adapt existing chimney or liner to stove When installing with B Vent liquid fuel gas chimney in...

Page 15: ...r 2000 085 Variable Speed Switch Fan 3000 930 Thermo Disc Spill Switch CONVERSION KITS For SIT Valve only 5000V CKLP LP Conversion Kit 5000V CKNG NG Conversion Kit BURNER ASSEMBLY AND VALVE SYSTEM PAR...

Page 16: ...alve Nova NG Hi Lo 0820634 1001 P713SI Pilot Burner LP 199 713 TC SIT 1001 P714SI Pilot Burner NG 199 714 TC SIT If Serial Number is GRETAER than 4740 only SYSTEM 3 New SIT TC True Millivolt Vented 50...

Page 17: ...switch wiring for ground May be grounded to appliance or gas supply Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while hold...

Page 18: ...ce or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoever incl...

Reviews: