Appliance/Log Reference Chart/Log Placement
The following is a list of models and appropriate log sets that can be used with each model. It is important that the appropriate
log set is used with the correct model in order for the appliance to work properly.
MQRSP1
MQRSP2
Appliance
LOGF36 MQROCK1
MQROCK1
MQHBZDV3636N or LP
✔
✔
MQHBZDV4236N or LP
✔
✔
HBZDV4736N or LP
✔
✔
Door and Glass Information
Glass Cleaning
It will be necessary to clean the glass periodically. During start-
up, condensation, which is normal, forms on the inside of the
glass and causes dust, lint etc. to cling to the glass surface.
Also, initial paint curing can deposit a slight film on the glass. It
is therefore recommended that initially the glass be cleaned two
or three times with non-abrasive common household glass
cleansers and warm water. After that, the glass should be
cleaned two or three times a season depending on the circum-
stances.
Glass Replacement
REPLACEMENT GLASS FOR BOTH DIRECT VENT UNITS
Model Series HBZDV4736 use Low E
Tempered Glass. Must be 5mm thick.
Only Robax ceramic or coated Neaoceram
glass may be used for replacement for model
MQHBZDV3636, MQHBZDV4236 and
MQRB4236. Must be minimum 5mm thick.
To replace glass, clean all materials from
door frame. Scrape off old silicone down to
metal. Using a high heat silicone tempera-
ture-resistant to 500°F (260°C) apply a con-
tinuous bead of approximately 1/32” to all four
sides of frame and insert glass with new gas-
ket. Frame should be on flat surface, with a
small amount of weight pressing glass into
silicone. Let dry approximately 15 to 20 min-
utes. The door can be re-installed by revers-
ing Steps 1 & 2. Use caution when removing
broken glass, wear gloves.
Removal of the Glass Door
1. Remove the door by unlatching the 2 top latches. Simply
place 2 fingers in the grooves, pull towards you and lift
upwards slightly.
2. Once the top of the door is unlatched, simply pull outwards
and lift upwards to unlatch the bottom.
3. When re-installing the door place the bottom of the door in
first and secure with Top Latch assembly to the door.
Spring Replacement:
*Over time, spring may need to be replaced if tension is lost.
1. To remove the top latch, remove the 2 hex screws that secure
it in place. They are located in the firebox.
2. Once all the screws are removed the latches will slide out of
place.
3. There is 1 lock nut per latch. When replacing a spring, tighten
the lock nut until 2 threads are beyond the locknut. This is crit-
ical for proper tension.
Warning and Cautions.
• Do not clean when the glass is hot.
• Do not use abrasive cleaners.
• Using a substitute glass will void all product
warranties.
• Do not strike or abuse glass. Care must be
taken to avoid breakage of the glass.
• Do not operate this fireplace without the glass
front or with a broken glass.
45
Summary of Contents for HBZDV4736
Page 24: ...Non Combustible Header Attached Non Combustible Header Attached 24...
Page 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...
Page 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...
Page 59: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 59...
Page 60: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 60...
Page 67: ...Proflame 2 Remote Control 67...
Page 69: ...69...