MQHBZDV4736- HOW TO INSTALL CLEAN VIEW KIT (CVCK)
CAUTION: When using CVCK DO NOT INSTALL a Louver assembly.
1. Install optional fan kit (see Fan Instruction).
2. Fold two standoffs up into position and mount with supplied screws. (FIG 1)
3. Hang CVCK on top of fireplace retainer tabs and rotate down into position. (FIG 2)
4. Using the screws provided, fasten the non-combustible header onto the top of the CVCK assembly.
5. Using four supplied #6 screws, fasten CVCK kit to the inside frame of unit.
6. Kit is supplied with 2 valve extension knobs. Align the notches and slide the extensions onto valve knobs.
7. DO NOT brick or tile beyond the inside area of the CVCK kit to allow for removal of door.
NOTE:
ADDITIONAL ACCESS FOR GASLINE INSTALLATION AND FAN ELECTRICAL INSTALLATION- When CVCK is
installed in framing, remove 2 screws from the right and left side of the bottom panel. Once screws are removed, bottom
panel can be rotated forward for access to gas valve and fan system.
Clearance to Combustibles
Clearance to Combustibles
Back (from Standoffs)
0 inches/0 mm
Side (from standoffs)
0 inches/0 mm
Floor
0 inches/0 mm
Ceiling (from bottom of fireplace)
60 inches/150 cm
Top (from standoffs)
0 inches/0 mm
Top of 90 degree bend in Minimum
with insulation sleeve
Enclosure of 50 1/2 to 56 1/2 inches
2 1/2 inches/64 mm / All Vent Systems
Top of 90 degree bend in
without insulation sleeve
Enclosure over 56 1/2 to 60 inches
4 1/2 inches/114.75 mm / All Vent Systems
Top of 90 degree bend in
without insulation sleeve
Enclosure over 60 inches
2 1/2 inches/64 mm / All Vent Systems
Side & Bottom of Horizontal Pipe
1 inch/25.5mm / All Vent Systems
Vertical Vent Pipe
1 inch/25.5mm / Kingsman Vent Systems
Vertical Vent Pipe
1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk
Direct Temp Systems
⚠
WARNING:
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
NOTE:
When using the
Clean View Kit (CVCK)
and installing optional
electrical components (i.e.
Remote Controls, variable
speed control, and or fan
modules) locate them in
the Clean View access
area, unless other
shielding devices like our
IPI Component box is
used.
(NOTE -Floor) if installing the
appliance directly on carpeting
or other combustible materials
other than wood flooring, the
appliance shall be installed on a
metal or wood panel, the full
width and depth of the
appliance. Carpet may extend 1
inch above the floor of
appliance.
For units with CVCK (Clean
View Circulating Kit) see framing
with CVCK to establish floor
heights.
25
Summary of Contents for HBZDV4736
Page 24: ...Non Combustible Header Attached Non Combustible Header Attached 24...
Page 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...
Page 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...
Page 59: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 59...
Page 60: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 60...
Page 67: ...Proflame 2 Remote Control 67...
Page 69: ...69...