Split Receptacle-
Fan Speed Control Outside of Fireplace
If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source
of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures
below.
WARNING
WARNING
WARNING
A qualified electrician must connect
electrical wiring to junction outlet for
built-in installation.
Follow all codes.
Electrical Grounding Instructions –
This appliance is equipped with a
three – pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into a
properly grounded three-prong
receptacle.
Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation and
servicing.
Caution
: Electrical installation to be done by a qualified installer. All wires must be connected and grounded in accordance with
CSA Standard C22.1- Canadian Electrical Code part 1 or with the National Electrical Code, ANSI /NFPA 70 (latest edition) and /or in
accordance with local codes.
Switch Controlled Split Receptacle With Switch At START Of Cable Run
Switch Controlled Split Receptacle With Switch At END Of Cable Run
31
Summary of Contents for HBZDV4736
Page 24: ...Non Combustible Header Attached Non Combustible Header Attached 24...
Page 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...
Page 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...
Page 59: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 59...
Page 60: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 60...
Page 67: ...Proflame 2 Remote Control 67...
Page 69: ...69...