Trouble Shooting The Gas Control System

WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT.

NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position.

Problem

Possible Causes

Corrective Action

Spark igniter will not light.

Defective or misaligned electrode

Check for spark at electrode and pilot: if no spark and electrode wire is

at pilot.

properly connected, replace igniter.

Defective igniter

Using a match, light pilot. If pilot lights, turn off pilot and push the red

(push-button)

button again. If pilot will not light - check gap at electrode and pilot 
should be 1/8” to 1/4” to have a strong spark.

Pilot will not stay lit after carefully

Defective thermocouple

Check pilot flame. Must impinge on generator and thermocouple.

following lighting instructions.

(flame switch where applicable) 

Clean and/or adjust pilot for maximum flame impingement on
generator and thermocouple.  Replace thermocouple if pilot will not 
hold.  (Hand tight 1/8 turn on replacement)

Defective valve magnet.

Replace valve, if pilot won’t hold after the thermocouple is replaced.

Pilot burning, no gas to burner,

Wall switch or wires

Check wall switch and wires for proper connections. Jumper wire

Valve knob “ON”, Wall

defective.

across terminals at wall switch. If burner comes on, replace defective

Switch “ON”

wall switch. If okay, jumper wires, across wall switch wires at valve.
If burner comes on, wires are faulty or connections are bad.

Generator may not be generating

Check generator with millivolt meter. Take reading at generator termi-

sufficient voltage.

nals of gas valve. Should read 325 millivolts minimum while holding 
valve knob depressed in pilot position and wall switch “off” Replace 
faulty generator if reading is below specified minimum.

Plugged burner orifice.

Check burner orifice for stoppage and remove.

Defective automatic valve

Remove wall switch wires from gas valve. Install jumper wires from 

operator.

top bottom terminals of gas valve. Turn valve on “ON”. If main burner
does not light, replace valve.

Frequent Pilot outage problem.

Pilot flame may be too low or

Clean and/or adjust pilot flame for maximum flame impingement

blowing (high) causing the pilot

on generator and thermocouple.

safety to drop out.

Flame lifts off burner and goes out

Inner 4” liner has come off flue

Attach 4” liner to flue or termination using      

in less than 30 seconds

or termination, flame is starving

screws, silicone and clamps as stated in manual

for oxygen

Flame lifts off burner on

Improper installation of firebrick.

Be sure to position firebrick against firebox walls and

one side while the rest of

Firebrick is likely leaning.

be sure to use brick clips attached to the inner side

the flame remains lit.

of firebox.

26

Summary of Contents for FDV300

Page 1: ...n of R Co Inc 2340 Logan Ave Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Read this complete manual before beginning installation These instructions must be kept with the unit for future reference...

Page 2: ...leave the area during the cure phase Ventilate well open doors and windows Do not touch during curing Why does my fireplace or stove give off odour It is normal for your fireplace to give off some od...

Page 3: ...brick panel kit 13 Optional fan kit installation 14 Millivolt system lighting burner control 15 Vent termination 16 General venting information 17 Vent pipe assembly 19 Horizontal vent installation 1...

Page 4: ...OBILE HOMES AFTER FIRST SALE THE MODELS CONVERTED USING THE B VENT CONVERTER CANNOT BE INSTALLED IN A MANUFACTURED MOBILE HOME Please follow the current ANSI NFPA 70 National Electrical Code in the US...

Page 5: ...ards of the high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing 3 Children should be carefully supervised when they are in the same room as your fir...

Page 6: ...Edition B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall a Be powered by the same electrical circuit as the appliance or equipment such that...

Page 7: ...other combustible material with no additional floor protection being required This unit has been tested in a Alcove the minimum size of Alcove is Depth 30 Height 55 5 Width 52 5 THE FOLLOWING MINIMUM...

Page 8: ...ss of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pr...

Page 9: ...Children and adults should be alerted to the hazards of high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing Control compartments burners and air pas...

Page 10: ...burner areas This appliance should not be used as drying rack for clothing nor should Christmas stockings or decorations be hung near it Under no circumstances should any solid fuels wood paper cardbo...

Page 11: ...OT OPERATE THIS STOVE WITHOUT THE GLASS DOORS OR WITH A BROKEN GLASS DOOR DO NOT STRIKE OR ABUSE GLASS GLASS REPLACEMENT Only Robax ceramic or coated Neoceram glass may be used for replacement It must...

Page 12: ...ing pan as shown in the picture Fig 4 Log B has 2 Locating holes position the 2 holes on the log over the 2 pins on the right side of the log mounting pan as shown in the picture Fig 5 Log C has to be...

Page 13: ...towards you slightly and pull your right hand towards you slightly and place panel onto the rear of the firebox NOTE TAKE CARE NOT TO DAMAGE PILOT ASSEMBLY WHEN PLACING REAR PANEL 4 Loosen both brick...

Page 14: ...d and gas line attached before proceeding 5 Turn the stove on Once the sensor unit reaches operating temperature in approximately 10 to 15 minutes the fan will turn on The fan can be switched off if d...

Page 15: ...pilot screw to provide proper sized flame Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire Size Max Length 14 GA 100 FT 16 GA 64 FT 18 GA 40 FT 20 GA 25 FT 22 GA...

Page 16: ...s follows top of horizontal pipe 21 2 top of 90 degree pipe 4 Vent Terminal Air Supply Area Where Terminal Not Permitted A Clearance above grade veranda porch deck or balcony 12 inches 30cm minimum 1...

Page 17: ...ct Temp Simpson Dura Vent for Masonry Chimney Conversion Kits may be used with this appliance Use your existing masonry chimney and route the exhaust gases intake air through the side of the masonry c...

Page 18: ...rmine the correct vent lengths for optimum stove performance HOW TO USE THE VENT TABLE 1 Determine the height of the system and the number of elbows required Total Vertical Max Total Horizontal Feet M...

Page 19: ...erature sealant MIL PAC SEALANT IS RECOMMENDED to the pipe and secure it with the 4 screws If two pieces of 4 flex pipe are to be joined the joint must be siliconed and secured with screws Before join...

Page 20: ...only time this may be unavoidable is when installing the vent terminal Note Do not remove or move spacer springs attached to 4 inner flex pipe these must be used to assure an 1 1 4 air gap between 4...

Page 21: ...to the top of the horizontal pipe must be maintained Maximum vertical height of system should not exceed 40 feet Spacer springs to be installed on 4 flex pipe every 3 ft on vertical runs On 45 elbows...

Page 22: ...ar of stove and Lower B Vent Converter onto the 4 and 7 inch collars until fully seated Screw the Converter to the stove with 2 of the 4 screws supplied 3 Place the decorative collar around the adapte...

Page 23: ...inch single wall or B Vent liquid fuel gas chimney or Flex Gas Liner may be used to adapt existing chimney or liner to stove When installing with B Vent liquid fuel gas chimney install as per B Vent M...

Page 24: ...l Installations ZDV4FP8 Flex Pipe 4 Diameter 4 Unexpanded to 8 Expanded ZDV4FP20 Flex Pipe 4 Diameter 10 Unexpanded to 20 Expanded ZDV4FC Flex Connector 4 Diameter Product Number Description FDV300N F...

Page 25: ...TOP CONVERTIBLE LP ASSEMBLED 199 713 1001 P714SI PILOT TOP CONVERTIBLE NG ASSEMBLED 199 714 1001 P633SI VALVE NOVA LP Hl LO 0820633 or 651 1001 P634SI VALVE NOVA NG Hl LO 0820634 or 652 1001 P216SI T...

Page 26: ...als at wall switch If burner comes on replace defective Switch ON wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generato...

Page 27: ...th service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoe...

Reviews: