The maximum number of 90° elbows per installation is three (3). For each additional 90° elbow, the horizontal
runs must be reduced by 36" per 90° elbow. See venting chart on page 14 for total horizontal and vertical runs.
For each 45° elbow installed in the horizontal run, the length of the horizontal run must be reduced by 18" (45 cm).
This does not apply if the 45° elbows are installed on the vertical part of the vent system. 45° elbows can be
installed in either the horizontal or vertical runs.
The minimum allowable
configuration is 4
1
/
2
feet vertical
with unit 4” from wall.
The maximum horizontal vent run
with one 90° elbow attached is 20
feet with 7 feet vertical.
The maximum vertical rise
is 40 feet.
WARNING:
Failure to position the parts in accordance with these diagrams or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury.
Only trim kit(s) supplied by the manufacturer shall be used in the installation of this appliance.
Draft Relief Openings must not be covered or blocked.
GENERAL VENTING INFORMATION
TERMINATION
It is imperative that the vent termination be located observing the minimum clearances as shown. There must
not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24" from the front
of the termination.
Do not locate termination where excessive snow or ice build-up may occur. Be sure to check vent termination
area after snow falls and clear to prevent accidental blockage of venting system. When using snow blowers,
This gas appliance is approved to be vented either through the side wall or vertically through the roof.
Only Kingsman
venting kits and components specifically approved and LABELED for this stove may be used
. This appliance is also
approved for use with Simpson-Duravent Direct Vent system, Model DV-GS Series, Ameri-Vent Direct Vent Pipe System
and Selkirk Direct Temp.
Simpson Dura-Vent for Masonry Chimney Conversion Kits
may be used with this appliance Use your existing masonry
chimney and route the exhaust gases intake air through the side of the masonry chimney. Use Simpson Dura-Vent kit
numbers 46DVA-KMC or 46DVA-KCT. Termination Cap, Kingsman/Dura-Vent adapter, and 4” flex are sold separately.
Simpson Dura-Vent for Factory built metal Chimney Conversion Kits
may be used with this appliance. Use your
existing through the ceiling, wood stove chimney and route the eshaust gases and intake air through the existing wood
burning metal chimney. Use Simpson Dura-Vent Kit numbers 46DVA-KCA for 6 5/8” to 8 5/8” OD sized chimney, 46DV-
KCB for 8 3/4” to 10 1/2” OD sized chimneys and 46DVA-KCC for 10 5/8” to 13” OD sized chimneys. Kits 931, 932, and
933 include a cap adapter and Retro Connector. Termination Cap, Kingsman/Dura-Vent adapter, and 4” flex are sold
separately.
SIMPSON DURAVENT, AMERIVENT OR SELKIRK DIRECT TEMP
When using Simpson Duravent, AmeriVent pipe or Selkirk Direct Temp a Duravent hardpipe adapter must be used
(ZDVDKA). Follow installation instructions provided by Simpson Duravent/AmeriVent/Selkirk Direct Temp for
installation of pipe and adhere to the clearance to combustibles provided in this manual. Apply a bead of Mill Pac high
temp sealant to all joints of pipes, adapters and termination, when using Kingsman venting and Simpson Duravent venting.
Minimum clearances on venting (
4" to top of elbow
), (
2-1/2" from top of horizontal pipes
), (
1" on all other existing
pipes
).
REMEMBER THAT A 1/4" VERTICAL RISE IS REQUIRED FOR EVERY 12" OF HORIZONTAL
RUN
.
Venting terminal shall not be recessed into a wall or siding. If finishing the outside wall with vinyl or wood siding it is
recommended that a Siding Shield be installed, Part Number ZDVSSLR.
VENTING ROUTES AND COMPONENTS
Since it is very important that the vent system maintain its balance between the
combustion air intake and the flue gas exhaust, certain limitations as to vent
configurations apply and must be adhered to.
WARNING:
DO NOT mix
parts from different systems
unless stated in the manual.