allowed on the joint of the indoor unit, as shown in Fig.19.
No gap
Fig.19
CAUTION!
After the pipe is protected well enough, never bend it to form a small angle; otherwise it would
crack or break.
(3). Wrap the pipe with tape.
1). Bundle the refrigerant pipe and electric wire together with tape, and separate them from the
drain pipe to prevent the condensate water overflowing.
2). Wrap the pipe from the bottom of the outdoor unit to the top of the pipe where it enters the
wall. During the wrapping, the later circle should cover half of the former one.
3). Fix the wrapped pipe on the wall with clamps.
CAUTION!
① .
Do not wrap the pipe too tightly; otherwise the insulation effect would be weakened.
Additionally, make sure the drain hose is separated from the pipe.
② .
After that, fill the hole on the wall with sealing material to prevent wind and rain coming into
the room.
3.15 Wiring between the Wire and the Wiring Terminal
(1). Wiring of the Single-Core Wire
1). Strip the insulating layer at the end of the wire about 25mm off with a wire striper.
2). Loosen the screw off on the wiring board of the air conditioning unit.
3). Shape with the pliers at the end of the wire to a circle matching with the size of the screw.
4).
Let the screw go through the circle of the wire and then fix it on the wiring board.
(2). Wiring of the Multi-Core Wire
1). Strip the insulating layer at the end of the wire about 100mm off with a wire striper.
2). Loosen the screw off on the wiring board of the air conditioning unit.
3). Fix a wiring terminal matching with the size of the screw to the end of the multi-core wire
with the crimpling pliers.
4).
Let the screw go through the terminal of the multi-core wire and then fix it on the wiring
board.