2 Installation Location and Matters Needing Attention
The installation of the unit must comply with the national and local safety
regulations. The installation quality directly affects the normal use, so the user should
not carry out the installation personally, instead, the installation and debugging should
be done by technician according to this manual. Only after that, can the unit be
energized.
2.1 How to select the Installation Location for the indoor unit
(1). Where there is no direct sunlight.
(2). Where the top hanger, ceiling and the building structure are strong enough to withstand the
weight of the unit.
(3). Where the drain pipe can be easily connected to outside.
(4).
Where the flow of the air inlet and outlet are not blocked.
(5). Where the refrigerant pipe of the indoor unit can be easily led to outside.
(6).
Where there is no inflammable, explosive substances or their leakage.
(7). Where there is no corrosive gas, heavy dust, salt mist, smog or moisture.
CAUTION!
The unit which is installed in the following places is likely to run abnormally. If unavoidable,
please contact the technician at the
.,1*+20(
appointed service center
:
①
Where is full of oil;
②
Alkaline soil off the sea;
③
Where there is sulfur gas(like sulfur hot spring);
④
Where there are devices with high frequency (like wireless devices, electric welding devices,
or medical equipments);
⑤
Special circumstances.
2.2 Electric Wiring
(1). The installation must be done in accordance with the national wiring regulations.
(2). Only the power cord with the rated voltage and exclusive circuit for the air conditioning can
be used.
(3). Do not pull the power cord by force.
(4). The electric installation should be carried out by the technician as instructed by the local
laws, regulations and also this manual.
(5). The diameter of the power cord should be large enough and once it is damaged it must be
replaced by the dedicated one.
(6). The earthing should be reliable and the earth wire should be connected to the dedicated
device of the building by the technician. Besides, the air switch coupled with the leakage
current protection switch must be equipped, which is of enough capacity and of both
magnetic and thermal tripping functions in case of the short circuit and overload.
2.3 Earthing Requirements
(1).
The air conditioner is classified into the Class I appliances, so its earthing must be reliable.
(2). The yellow-green line of the air conditioner is the earth line and can not be used for other