![Kingfer Industrial KF-009D-03 User Manual Download Page 6](http://html.mh-extra.com/html/kingfer-industrial/kf-009d-03/kf-009d-03_user-manual_1970189006.webp)
The heater must only be used when:
The heater is mounted upper the gas bottle. The heater radiant element must always
face away for the cylinder with the hose trailing at the rear of the appliance. The heater
must never be used separated from its holder unit.
FOR PILOT BURNER IGNITION:
Pilot/
Pos. 1
Pos. 2
(High)
Pos.3
(Min)
1. Make sure the assembled heater is in a right position. Connect the regulator to the
gas cylinder valve following the instructions supplied with the regulator to ensure
correct connection.
2. Turn on the cylinder valve or regulator switch and check for leakage on the regulator
connection with soapy water or leak detection fluid. If bubbles are showing the
connection has a leak. Turn off the cylinder valve or regulator switch and consult your
gas supplier to rectify the leak. Do not use the heater if it has a leak.
3.
for the heater WITH PILOT BURNER ignition
Press the gas control Knob at
Pos.1
, keep pressing down the knob for 30s for move
out the air from the gas hose. And then Ignite the radiant heater immediately pressing
the igniter (risk of ignition), This will light up the pilot flame, hold in the control knob for
a further 10 seconds. The pilot should stay alight. If the pilot does not stay alight, wait
2 minutes and retry this sequence. Once the pilot flame stay alight, press down the
knob lightly and turn the knob to
Pos.2
to set the power at maximum.
4. To adjust the heat power to minimum, press down the knob lightly and turn the knob
to
Pos.3
5. To turn the heater off. The heater can only be turned off by closing the cylinder valve.
5. Never disconnect the regulator form the cylinder whilst the heater is alight. Always
check that the burner is out first before disconnection the regulator.
CONNECTING TO THE CYLINDER
Summary of Contents for KF-009D-03