![Kingfer Industrial KF-009D-03 User Manual Download Page 12](http://html.mh-extra.com/html/kingfer-industrial/kf-009d-03/kf-009d-03_user-manual_1970189012.webp)
Technical
problems
Problem
Problem Causes
What To Do
Smell of gas
Regulator & hose connection loose
Use soap form for leakage control, check all
connection system replace defected parts
Valve & pipe connection loose
Pipe broken
Missing piece of ceramic fireclay
Inspect perimeter of each plaque and locate
place where some fireclay has been displaced.
Repair with PYRUMA and leave to set for
Approx. 48 hours.
Inefficient combustion on
ceramic burner
Dirty gas inlets
Please clear injectors with Air
If there is no ignition
Defective ignitor
Check ignitor & replace defected ignitor if
necessary
Defective Spark - Plug
Check cable of ignitor, & replace defected
ignitor if necessary
Defective ignitor cable
Check spark
– plug and connections, &
replace defected ignitor if necessary
Burner flame has extinguish
during operation
Run out of gas
Change the gas bottle
Thermal element has not been
warm enough
Try restarting
Wing or draught has extinguished
the flame
Put the appliance out of reach of wind and
draught, let it cool down for a couple of
minutes and try to restart it
Faulty thermocouple
Replace the faulty thermocouple
Faulty magnetic valve
Replace the magnetic valve
general
problem
Heater is not remain alight
when pressure is released
from ignition button
Wrong power setting at first process
Turn the control knob at “ START” Position
and press for 10 seconds, whilst press the
Piezo igniter key to lit
Heater could not be turned
on
Did not connect the gas regulator to
gas cylinder
Connect heater to the gas cylinder and ensure
there is not smell, then follow the Instruction to
turn on the heater
Gas cylinder control is closed
Please turn on the gas cylinder control
11