background image

 

 

 

  _________________________________________________________________________________________ 

      Page 2 of 15                  King Pigeon Communication Co.,Limited.              Ver 1.5    File No.:RTU5025103 

A Professional GSM 3G M2M products manufacturer 

and automation solution provider, since 2005.

 

www.GSM-Gate-Opener.com    [email protected]

 

Table of contents 

1.  Product  details  --------------------------------------------------------------------------3

 

1.1  Features------------------------------------------------------------------------------------------------------- 3

 

1.2  Specifications------------------------------------------------------------------------------------------- 3

 

1.3  Dimensions---------------------------------------------------------------------------------------------- 3

 

1.4  Standard  Packing  List  and  Model  Tabel----------------------------------------------------------------------4

 

1.5  Applications ------------------------------------------------------------------------------------------ 4

 

2.  Safety  Directions  -----------------------------------------------------------------------4

 

3.  Diagram  -----------------------------------------------------------------------------------5

 

4.  Typical  Wiring  Connection------------------------------------------------------------6

 

5.  Setting  by  PC  software----------------------------------------------------------------7

 

5.1  Basic  Settings-------------------------------------------------------------------------------------------------------7

 

 

5.2  Authorized  number  list  managerment------------------------------------------------------------------------8

 

 

5.3  Historical  data----------------------------------------------------------------------------------------------------------8

 

6.  Setting/Operating  by  SMS  commands  --------------------------------------------9

 

6.1  Change  password --------------- -------------------- -------------------------------------------- 10

 

6.2  Authorized  number  managerment --------------------------------------------------------------- 10

 

6.3  Relay  control  parameters --------------------------------------------------------------------------11

 

6.4  Digital  Input  parameters---------------------------------------------------------------------------------- 12

 

6.5  Self-check  auto  report/inquiry  status/historical  data/IMEI  code  and  firmware  version -----13

 

6.6  Data  function------------------------------------------------------------------------------------------ 14

 

7.  Important  information  ----------------------------------------------------------------15

 

8.  Maintenance----------------------------------------------------------------------------15

 

9.  Warranty  --------------------------------------------------------------------------------15

 

 

 

 

 

 

 

Caution! 

Please read this user manual carefully before install/operate the Gate 

Opener,basic electronic acknowledges required. 

This handbook has been designed as a guide to the installation and operation of RTU5025 Gate Opener. 

Statements contained in the handbook are general guidelines only and in no way are designed to supersede the 

instructions contained with other products. 

We recommend that the advice of a registered electrician be sought before any Installation work commences. 

King Pigeon Communication.Co.,Limited. its employees and distributors, accept no liability for any loss or damage 

including consequential damage due to reliance on any material contained in this handbook.   

King Pigeon Communication.Co.,Limited. its employees and distributors, accept no liability for GSM Network 

upgrading or SIMCard upgrading due to the technology specifications contained in this handbook.

 

Summary of Contents for RTU5025 Series

Page 1: ...ith a FREE call from your mobile phone Remote switching machines with a FREE call from your mobile phone User Manual Ver 1 5 RTU5025 Series Date Issued 2015 03 25 All rights reserved by King Pigeon Co...

Page 2: ...inquiry status historical data IMEI code and firmware version 13 6 6 Data function 14 7 Important information 15 8 Maintenance 15 9 Warranty 15 Caution Please read this user manual carefully before i...

Page 3: ...m authorized number then carries out the turn ON OFF action on the first ring Secure Using Caller ID for verification unknown phone calls are ignored SMS confirmation of relay actions door open to the...

Page 4: ...tors lights pumps generators valves and machines 2 Safety Directions Safe Startup Do not use Gate Opener when using GSM equipment is prohibited or might bring disturbance or danger Interference All wi...

Page 5: ...twork Flash per 2 seonds Normal status OFF can t connect to SIM card or unregistered to the cellular network Connection Terminals Power Power supply input Positive wire Red _ Power supply input Negati...

Page 6: ...M Gate Opener com Support GSM Gate Opener com 4 Typical wiring connection 1 RTU5025 for Gate opener Connect the door sensor to DIN1 for door status detection and siren for alarm sound the lock switche...

Page 7: ...s CP210x USBto UART Bridge for example COM3 Click here to know how to find out the COM Port on your computer 7 Run this configurate software select the COM Port number for example COM3 click Open the...

Page 8: ...format to the PC under the configuration folder Export csv Export the authorized number list csv format to the PC under the configuration folder All Always Select all the numbers as Always can call in...

Page 9: ...you cannot call to control the RTU5025 or cannot send or receive any SMS message from it please try to add in front of the country code or the phone numbers 8 Export the Authorized number list to xls...

Page 10: ...n and always can call in to control E g 1234A016 123456 1502050800 1502051000 to set the phone number 123456 at the 16th position this number can call in to control during Feb 5th 8 00a m 1502050800 t...

Page 11: ...then open OFF after call in 6 3 4 Who will receive the confirmation SMS when the relay is ON OFF for relay ON for relay OFF ab the ID code of the 1st number a and the caller number b 0 means disable...

Page 12: ...out RTU5025 will call the 1st number and next number if there have no answering 6 4 1 Arm Disarm 6 4 2 Define the DIN1 DIN2 type Eg 1234DIN2NO define the DIN2 as NO Normally Open type 6 4 3 Modify th...

Page 13: ...g Arm Disarm Status DIN1 2 status Relay status GSM signal value full is 31 cellular signal weak if lower than 14 AC DC power supply status Inquiry the self check and auto report time 6 5 3 Inquiry cur...

Page 14: ...n 100pcs RTU5025 only for small project we suggest client using PC software to configurate or read historical data via USB cable or SMS 6 6 1 Enable data function Disable data function 6 6 2 APN call...

Page 15: ...If the RTU5025 works but fail to send SMS texts switch the power off and on again after one minute Test it after few minutes later or ensure and check the settings are correct and the cellular signal...

Reviews: