Page 14 of 16 King Pigeon Hi-Tech. Co., Ltd. Page 14 of 16 Ver 1.0 File No.:RTU501610
A Professional GSM Alarm System designer and manufacturer!
GSM Transformer Alarm System &GSM House Alarm System&
GSM Telemetry Units & GSM GPRS Logging System
Http://www.GSMalarmsystem.com [email protected]
Please learning this button to T1 Position.
The +/- buttons on IR’s panel had used for switch on the Air-Conditioner and setup the temperature
at T2~T6 positions.
Example:
Learning 20
℃
to T2 position. You can following below steps.
1) Change the IR Value to 19
℃
or 21
℃
firstly, then Press the GSM SMS IR Controller learning
button, it will flick T1 firstly, press again, it flicks T2, when the T2 Led flicking, and Status Led is
Red and green color, then press the +/- on the IR’s panel to change the temperature to 20
℃
button. after the GSM SMS IR Controller received the signal, will save it at position T2.
2) When you want to learn the Switch OFF button function to the GSM SMS IR Controller, then
press the Learning Button, when the T1 Led flicks and status led is red and green color, then
press the Switch Button, the GSM SMS IR Controller will receive this signal and save at position
T1.
3) So when you send SMS command
, the GSM SMS IR Controller will switch on
the Air-Conditioner and change to Tx temperature, if you want to change its temperature, then
you can send SMS command
to change it again.
7.3 Connecting the temperature diode( 25°=10K,1% precision, included in standard package), the
connector points are Temp+ and Temp-, the temperature diode is non-polar.
7.4 Connecting the Electricity equipments
The GSM SMS IR Controller supports 1 Digital Output Relay(3A240VAC, NC and NO), it can be used
for remotely switch ON/OFF equipments by SMS Text Command, Also the relay can be linked to the
temperature threshold value, e.g.: when temperature is lower or higher than the threshold value, then
pwd#Tx#
pwd#Tx#