occurrence is default.
6.8 Switch ON the Relay Output
Reply:
Tips:
The Relay output cannot work while external AC Power goes off. The SMS Command has
priority over the Link configurations, e.g.: when setup
Switch On the Relay Output when High
temperature alarm occurrence function, and happened, the relay output will switch on, but when
the GSM SMS IR Controller received the SMS command pwd#DD#
, the relay output will switch off
immediately.
6.9 Switch OFF the Relay Output
Reply:
6.10 Switch ON Air-Conditioner and setup its temperature
The Tx stands for T2~T6.(T1 is special for switch off the air-conditioner, please see 6.11)
For example, send
pwd#T2#
to switch on the air-conditioner and setup the temperature as T2 position
value, will return
Send
pwd#T3#
to change the air-conditioner temperature to T3 Position Value, will return
If the Tx hasn’t been assigned any IR value, after send
pwd#Tx#
to the GSM SMS IR Controller, will
return
, eg.: if the T6 Position hasn’t been assigned the IR Value, then after send
pwd#T6#
to
the GSM SMS IR Controller, will return
(The T1~T6 value can be assigned to the GSM SMS IR Controller by used the Air-Conditioners’ IR
Transmitter.)
6.11 Switch OFF Air-Conditioner
Will return
.
7. Operation & Installation
Temp set 1 is PowerOff
pwd#OFF #
T6---;
Tx---;
Temp set3 is En;
Temp set2 is En;
pwd#Tx#
Relay: OFF.
pwd#DD#
Relay: On.
pwd#CC#