Before installing the GSM SMS IR Controller, please help to test the system firstly, including power supply, 

gsm signal, etc. 

7.1 Insert SIMcard into GSM SMS IR Controller 

In one side of the GSM SMS IR Controller, please install the GSM SIM card and GSM Antenna.   

 

7.2 Learning IR Transmitter signal to GSM SMS IR Controller. 

Step1:

 Press the Learning Button and switch on the GSM SMS IR Controller, then loose it and the GSM 

SMS IR Controller will remove all saved IR Transmitter signals at T1~T6. And enter into learning 

mode. The T1 Led will flick, and the Status Led will be red and green color. 

 

Step2:

 Press the Learning Button till the Status Led change to green and T1 Led flicking. Then press the 

IR(Infrared Remote of the Air-Conditioner) function button(The one what you want to learn to the 

GSM SMS IR Controller, for T1, it is special for the ON/OFF function. So please press the switch 

ON/OFF button ), when T1 Led change always on and Status LED turns off, then means the 

learning IR Signal to GSM SMS IR Controller T1 position operation successful. 

Step3:

 Press the Learning Button again, T1 LED will off, T2 Led will flick, press the IR function button, 

when T2 Led change to Green and Status LED turns off, then means the learning IR Signal to 

GSM SMS IR Controller T2 position operation successful. 

Tips: 

  The Switch Button on IR’s panel only used for switch off the Air-Conditioner in the RTU5016. 

Summary of Contents for GSM SMS IR CONTROLLER RTU5016

Page 1: ...GSM Telemetry Units GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn Automatically monitoring Air Conditioner by SMS Text Remotely Control Air Conditioner by SMS Text Tempe...

Page 2: ...ty 15 This handbook has been designed as a guide to the installation and operation of RTU5016 GSM SMS IR Controller Statements contained in the handbook are general guidelines only and in no way are d...

Page 3: ...authorized temperature monitoring remote control Air Conditioner Actually the GSM SMS IR Controller RTU5016 can be used in places which require to use Infrared Remote to control e g Air Conditioner Te...

Page 4: ...o owners low than 10 should automatically switch on the heater Air Conditioner to heat up the temperature and warning owners by SMS 6 Switch ON OFF equipments e g motor Air Conditioner and other elect...

Page 5: ...been reset to default settings Learning This button for learning IR Air Conditioner s Infrared Remote Transmitter OFF T1 6 T1 Position Led when learning IR signal to T1 will flick after learned succe...

Page 6: ...de 25 10K 1 precision included in standard package input to convert the temperature to digital value 2 Lower or Higher warning temperature threshold value can be configured 3 Can inquire the current t...

Page 7: ...tc Don t add spaces or any other character When input punctuation symbol must be under ENGLISH or DIGITAL input method Not support other input method 5 When external AC goes off and goes on will send...

Page 8: ...s 1234 then you can send 1234 TEL004413500001111 01 to the RTU5016 unit After the RTU5016 received the 0044 is country code will return For example In UK the country code is 0044 or 44 The user cell p...

Page 9: ...thorized Number 6 5 Inquiry the assigned IR value information After the RTU5016 received will return Tips The GSM SMS IR Controller can be saved 5 different temperature value The T1 position is for as...

Page 10: ...itch On the Air Conditioner automatically when low temperature alarm occurrence Reply Tips in Tx the x 1 6 Stands for T1 T6 This command means when low temperature alarm will switch on the Air Conditi...

Page 11: ...temperature alarm occurrence Reply 7 Switch On the Air Conditioner automatically when High temperature alarm occurrence Reply Tips The Tx is the same means of abovementioned x 1 6 Please pay attentio...

Page 12: ...immediately 6 9 Switch OFF the Relay Output Reply 6 10 Switch ON Air Conditioner and setup its temperature The Tx stands for T2 T6 T1 is special for switch off the air conditioner please see 6 11 For...

Page 13: ...l saved IR Transmitter signals at T1 T6 And enter into learning mode The T1 Led will flick and the Status Led will be red and green color Step2 Press the Learning Button till the Status Led change to...

Page 14: ...d the signal will save it at position T2 2 When you want to learn the Switch OFF button function to the GSM SMS IR Controller then press the Learning Button when the T1 Led flicks and status led is re...

Page 15: ...mission range and there re with a power source as well as enough GSM signal coverage The distance from the GSM SMS IR Controller must be less than 3meters to the Air Conditioner 8 Technical specificat...

Page 16: ...ler off and switch it on after one minute Test this system after another minute or check the settings are correct and the GSM Signals are strong enough 3 If the GSM SMS IR Controller can run and senso...