OIL & WATER VALVES
Installation, Operation & Maintenance Guide
29
www.kimray.com
Model: TREATER / DUMP
TESTING
22 Flow Direction, Check For Leakage
Flow Direction
Make sure the air is flowing from upstream to
downstream. Regulators have an arrow showing the
direction of flow.
Check for Leakage
Turn supply air off and make sure the Gauge is holding
pressure on the upstream side. If Gauge falls off then
you have leakage.
Check if any leakage is coming out the downstream side.
Spray soaped water on Housings, Breather Plugs and
Plugs. The identification of leakage will be noted if any
bubble shows up.
Treater Valve Test
Once no leakage is detected, close upstream flow.
NOTE:
Make sure the regulator holds various levels of pressure.
(100 psi down to 5 psi by turning the Adjusting Screw
out).