Model: TREATER / DUMP
16 Bonnet
Lift Link Hub slightly and place Bonnet over Stem
Assembly and onto Stem Diaphragm Assembly.
See Fig. 16-1
Fig. 16-2 shows correct orientation of Bonnet to
Body.
NOTE:
Make sure you tighten the Bolts in a criss-cross
pattern to avoid any miss alignment. For 2 in., 3
in., 4 in. and 6 in. tighten Bolts from 25-30 ft/lbs
torque.
Link Hub
Stem Diaphragm
Assembly
ASSEMBLY
Fig. 16-1
Fig. 16-2
Bonnet