OIL & WATER VALVES
Installation, Operation & Maintenance Guide
25
www.kimray.com
Model: TREATER / DUMP
ASSEMBLY
17 Stem
Insert Key onto Stem and insert Stem Assembly into
Keyway on large diameter of Shaft.
Line up Key with the Keyway inside the Link Hub and
slide Shaft and Key into Hub. Long end of Shaft will be
oriented opposite the pressure port of the Diaphragm
Housing.
NOTE:
Use all purpose grease or use never seize on Shaft.
Insert long side of Stem opposite of vent line hole.
Use all purpose grease onto
key and insert into slot of
Shaft.
Fig. 17-1