Kilsen KAL760 Installation Sheet Download Page 3

P/N 10-5151-501-106-02 • ISS 15JUN20 

 

3 / 20 

Manufacturer 

UTC CCS Manufacturing Polska Sp. 
Z o.o. Ul. Kolejowa 24. 39-100 
Ropczyce, Poland 

Authorized EU manufacturing 
representative: UTC Fire & Security 
B.V. Kelvinstraat 7, 6003 DH Weert, 
Netherlands  

 

2012/19/EU (WEEE directive): 
Products marked with this symbol 
cannot be disposed of as unsorted 
municipal waste in the European 
Union. For proper recycling, return 
this product to your local supplier 
upon the purchase of equivalent new 
equipment, or dispose of it at 
designated collection points. For 
more information see: recyclethis.info. 

Contact information and product 
documentation 

For contact information or to download the latest product 
documentation, visit firesecurityproducts.com. 

Product warnings and disclaimers 

THESE PRODUCTS ARE INTENDED FOR SALE TO AND 
INSTALLATION BY QUALIFIED PROFESSIONALS. UTC 
FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE 
THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, 
INCLUDING ANY “AUTHORIZED DEALER” OR 
“AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR 
EXPERIENCED TO CORRECTLY INSTALL FIRE AND 
SECURITY RELATED PRODUCTS. 

 

For more information on warranty disclaimers 
and product safety information, please check 
https://firesecurityproducts.com/policy/product-
warning/ 
or scan the QR code: 

 

ES: Instrucciones de instalación 

Descripción 

El módulo KAL760 proporciona una entrada remota a un 
sistema de detección de incendios direccionable.  

La señal de entrada se controla constantemente y se transmite 
su estado al panel de incendios. El módulo puede presentar 
cinco posibles estados: modo de reposo, circuito abierto, 
cortocircuito, alarma 1 y alarma 2. 

Nota: 

El estado de la entrada es enclavado (no es 

configurable) y vuelve al modo reposo después de un rearme 
del sistema. 

La entrada no tiene polaridad y puede activarse cerrando un 
contacto libre de potencial. El módulo puede utilizarse con 
cualquier dispositivo y la opción de contacto utilizada (C, NC o 
NA) establecerá el evento deseado. 

Instalación 

Precaución: 

Consulte el estándar EN 54:14 y las normativas 

locales para obtener información acerca de las directrices de 
planificación, diseño, instalación, funcionamiento, utilización y 
mantenimiento del sistema. 

Instalación del módulo 

Desconecte la fuente de alimentación del sistema de incendios 
e instale el módulo en la carcasa protectora proporcionada.  

Conecte el hilo apantallado del cable de bucle al tornillo de 
tierra  

La alimentación de 24 V del módulo se puede obtener del 
bucle o de una fuente de alimentación auxiliar.  

Si 10 o más módulos KAL700 se conectan al bucle, se debe 
utilizar una fuente de alimentación auxiliar. 

Conexión 

Los conectores del módulo, el microinterruptor y el indicador 
LED de estado se muestran en la Figura 1: 

1.  Tornillo de tierra 
2.  Conectores de bucle 
3.  Conexiones de alimentación auxiliares 
4.  Conectores de entrada 
5.  Microinterruptor 
6.  LED de estado 

Sobrecarga del bucle 

Compruebe siempre las instalaciones de gran tamaño con una 
calculadora de carga para confirmar que hay suficiente 
alimentación en el bucle. 

Nota: 

para evitar la sobrecarga del bucle cuando se utilicen 

dispositivos con alimentación mediante bucle, consulte las 
directrices de instalación y configuración del sistema en la 
Nota de aplicación de los módulos de E/S y de alimentación 
mediante bucle. Su distribuidor local puede proporcionarle este 
documento. 

Configuración de la fuente de alimentación 

Para establecer la fuente de alimentación del módulo, retire la 
cubierta de la unidad y configure los puentes JMP1 y JMP2. 

 

 

Configuración de los puentes 
con alimentación mediante 
bucle. 

Configuración de los puentes 
de la fuente de alimentación 
auxiliar de 24 VCC. 

ADVERTENCIA: 

no conecte una fuente de alimentación 

auxiliar de 24 VCC al módulo si se proporciona alimentación 
mediante un bucle. 

Summary of Contents for KAL760

Page 1: ...m The input signal is constantly monitored and its status communicated to the fire panel The module has five possible states standby open circuit short circuit alarm 1 and alarm 2 Note The input state...

Page 2: ...to a different state 270k standby 100k alarm 1 39k alarm 2 The maximum tolerance range is 5 Addressing Each module requires a numeric address between 128 and 252 for identification purposes This is s...

Page 3: ...errando un contacto libre de potencial El m dulo puede utilizarse con cualquier dispositivo y la opci n de contacto utilizada C NC o NA establecer el evento deseado Instalaci n Precauci n Consulte el...

Page 4: ...oporciona un resumen de las prestaciones declaradas seg n el Reglamento sobre los productos de construcci n UE 305 2011 y los Reglamentos delegados UE 157 2014 y UE 574 2014 Para obtener informaci n d...

Page 5: ...fico per assicurarsi che sia disponibile una potenza sufficiente Nota Per evitare il sovraccarico del loop quando si utilizzano dispositivi alimentati dal loop vedere le indicazioni per l installazion...

Page 6: ...umentazione del prodotto pi recente visitare firesecurityproducts com Avvertenze sul prodotto e dichiarazioni di non responsabilit QUESTI PRODOTTI SONO DESTINATI ALLA VENDITA A E DEVONO ESSERE MONTATI...

Page 7: ...DIP 1 7 Consulte a tabela de endere amento no final desta documento LED de estado O LED de estado est constantemente aceso durante o alarme Manuten o e testes A manuten o b sica limita se a uma inspe...

Page 8: ...ille circuit ouvert court circuit alarme 1 et alarme 2 Remarque L tat de l entr e est verrouill ce n est pas configurable et revient en veille apr s une r initialisation du syst me L entr e n a pas de...

Page 9: ...C alim aux veille 24 VCC alim aux alarme 200 A 50 mA Consommation lectrique alimentation par la boucle Consommation lectrique boucle Veille Alarme 750 A 3 6 mA Certification et conformit Cette section...

Page 10: ...aangegeven in Figuur 1 1 Aardeschroef 2 Lusconnectoren 3 Externe voedingsconnectoren 4 Ingangsconnectoren 5 DIP switch 6 Statuslampje Overbelasting lus Controleer bij grote installaties altijd met ee...

Page 11: ...voor meer informatie recyclethis info Contactgegevens en productdocumentatie Ga naar firesecurityproducts com voor contactgegevens of om de nieuwste productdocumentatie te downloaden Waarschuwingen e...

Page 12: ...sv t trvale p i poplachu dr ba a zkou en Z kladn dr ba se omezuje na kontrolu prov d nou jednou za rok Neupravujte vnit n veden ani obvody Zkou en modulu 1 P ive te do jednotky vstupn sign l a zkontr...

Page 13: ...asjon Forsiktig For generell veiledning om planlegging utforming installasjon oppstart bruk og vedlikehold av systemer kan du se EN 54 14 standarden og lokale forskrifter Modulinstallasjon Frakoble st...

Page 14: ...odusentens representant Europa UTC Fire Security B V Kelvinstraat 7 6003 DH Weert Nederland 2012 19 EU WEEE direktiv Produkter merket med dette symbolet kan ikke kastes med usortert kommunalt s ppel i...

Page 15: ...trzy rezystory patrz rysunek powy ej pozycja 7 8 9 odpowiadaj ce trzem r nym stanom 270 k czuwanie 100 k alarm 1 39 k alarm 2 Maksymalny zakres tolerancji wynosi 5 Adresowanie Ka dy modu wymaga ustawi...

Page 16: ...tos t c mezhet t z rz kel rendszerekhez A bemen jelet a rendszer folyamatosan figyeli s llapot t k zli a t zolt pulttal A modulnak tf le llapota lehet k szenl t resj rat r vidz r 1 riaszt s 2 riaszt s...

Page 17: ...d T meg 370 g M ret 182 142 77 mm ramfelv tel k ls t pl l s eset n A hurok ramfelv tele 24 V egyen ramr l k szenl t 35 V egyen ramr l k szenl t Riaszt s 110 A 135 A 10 mA ramfelv tel 24 V egyen ram k...

Page 18: ...M TUDJA BIZTOS TANI HOGY A TERM KEIT MEGV S ROL TERM SZETES VAGY JOGI SZEM LY BELE RTVE A HIVATALOS FORGALMAZ T S A HIVATALOS VISZONTELAD T MEGFELEL EN K PZETT ILLETVE TAPASZTALT A T ZV DELMI S BIZTON...

Page 19: ...P N 10 5151 501 106 02 ISS 15JUN20 19 20...

Page 20: ...60 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 2...

Reviews: