TOS
6200/6210
4-5
4.
2
.
2
T
est Frequency
Selec
t
t
he f
r
eq
u
ency
o
f
t
he
t
es
t
c
urr
en
t,
50
or
6
0
Hz
.
Y
ou
c
a
n se
t
t
he
t
es
t
f
r
eq
u
ency
u
sin
g
t
he SH
I
FT + F
1
key c
o
mbin
at
i
o
n (p
r
essin
g
t
he
F
1
key while h
o
ldin
g
d
o
wn
t
he SH
I
FT key
.
)
Pr
essin
g
SH
I
FT + F
1
togg
les be
t
ween
50
Hz
a
nd 6
0
Hz se
tt
in
g
s
.
Y
ou
c
a
n
a
ls
o
u
se
t
he
▲▼
keys
to
m
o
ve
t
he c
ur
s
or
to
t
he
t
es
t
f
r
eq
u
ency indi
-
c
at
i
o
n
.
Wi
t
h
t
he c
ur
s
or
at
t
he
t
es
t
f
r
eq
u
ency indic
at
i
o
n
,
u
se
t
he
rotar
y kn
o
b
to
se
t.
T
ur
nin
g
t
he kn
o
b cl
o
ckwise:
6
0
Hz
T
ur
nin
g
t
he kn
o
b c
ou
n
t
e
r
cl
o
ckwise:
50
Hz
4.
2
.3
U
pper
R
eference Value
I
f
t
he me
a
s
ur
ed v
a
l
u
e exceeds
t
he se
t
r
efe
r
ence v
a
l
u
e
,
t
he
t
es
t
is j
u
d
g
ed F
AI
L
.
The f
o
ll
o
win
g
j
u
d
g
men
t
me
t
h
o
ds
ar
e
a
v
a
il
a
ble:
■
S
election of the judgment method (
TOS6210
only)
The TOS6
210
a
ll
o
ws y
ou
to
selec
t
r
esis
ta
nce v
a
l
u
e
-
b
a
sed j
u
d
g
men
t
or
s
a
mpled
v
o
l
tag
e v
a
l
u
e
-
b
a
sed j
u
d
g
men
t.
Pr
ess
t
he SH
I
FT
a
nd F4 keys
tog
e
t
he
r
to
swi
t
ch be
t
ween j
u
d
g
men
t
me
t
h
o
ds
.
E
a
ch
t
ime y
ou
p
r
ess
t
he SH
I
FT
a
nd F4 keys
,
t
he
u
ppe
r
r
efe
r
ence v
a
l
u
e
a
l
t
e
r
n
at
es be
t
ween
a
r
esis
ta
nce v
a
l
u
e
a
nd v
o
l
tag
e v
a
l
u
e
.
Judgment Method
TOS
6200
TOS
6210
Resis
ta
nce v
a
l
u
e
-
b
a
sed j
u
d
g
men
t
A
v
a
il
a
ble
A
v
a
il
a
ble (ei
t
he
r
m
a
y
be selec
t
ed)
S
a
mpled v
o
l
tag
e v
a
l
u
e
-
b
a
sed j
u
d
g
men
t
Not
a
v
a
il
a
ble
25.0
A
0.100
60.0
s
M
AIN
M
AIN
F
RE
Q
L
O
W
ER
O
FF
O
FF
SET
O
FF
TI
M
ER
ON
REA
D
Y
50
H
z
F
1
F
2
F3
F4
F5
SHI
F
T
F
RE
Q
50/60
H
z
L
O
W
ER
ON
/
O
FF
O
FF
SET
ON
/
O
FF
TI
M
ER
ON
/
O
FF
U
PP
ER
25.0
A
0.100
60.0
s
M
AIN
M
AIN
F
RE
Q
L
O
W
ER
O
FF
O
FF
SET
O
FF
TI
M
ER
ON
REA
D
Y
50
H
z
F
1
F
2
F3
F4
F5
SHI
F
T
F
RE
Q
50/60
H
z
L
O
W
ER
ON
/
O
FF
O
FF
SET
ON
/
O
FF
J
U
DG
E
R
/V
TI
M
ER
ON
/
O
FF
U
PP
ER
25.0
A
2.50
V
60.0
s
M
AIN
M
AIN
F
RE
Q
L
O
W
ER
O
FF
O
FF
SET
O
FF
TI
M
ER
ON
REA
D
Y
50
H
z
F
RE
Q
50/60
H
z
L
O
W
ER
ON
/
O
FF
O
FF
SET
ON
/
O
FF
J
U
DG
E
R
/V
TI
M
ER
ON
/
O
FF
U
PP
ER
S
ampled
voltage
value-based
judgment
Press
the
SHI
F
T
and
F4
keys
together.
R
esistance
value-based
judgment
Summary of Contents for tos6200
Page 1: ...Part No Z1 003 302 IB008755 Aug 2011 OPERATION MANUAL EARTH CONTINUITY TESTER TOS6200 TOS6210...
Page 36: ...3 8 TOS6200 6210...
Page 130: ...6 52 TOS6200 6210...
Page 136: ...7 6 TOS6200 6210...
Page 154: ...A 10 TOS6200 6210...